4. OPERATING AND PROGRAMMING THE SM40 SYSTEM
4-27
4
Installer Programming Menu: Configure Call Stations: Configure Extended Call Station
The Extended Call Station programming option makes it possible to configure 1 to 4 Call Stations with
more than 10 keys.
The (key-) stations connected to input cards 5, 6, 7 and 8 can be coupled to Call Stations 1, 2, 3 or 4 but
the total number of assigned key sets (including the Master Call Stations) can never exceed 16 (160 keys).
Every (key-) station of the coupled key sets behaves like a normal Call Station. A hardware addition is
necessary when the LED indicators of the Call Stations and Key Stations need to be coupled.
Status / Action
After pressing ‘
C
’ in the Main Installer Menu
the display shows:
Possible display after pressing the ‘
1
’ key:
After pressing ‘
Enter
’ the display shows:
Entering the Extended Call Station number.
If the number of a non present Extended Call
Station is entered the display shows:
Otherwise, when the selected Extended Call
Station is in use the display shows:
Result / Remarks
The four blocks of characters at the lower line on the display represent inputs 17 to
32 of input cards 5 to 8.
*** ERROR *** STATION ALREADY ASSIGNED
PRESS 'ENTER'
*** ERROR *** CALL STATION NOT IN SYSTEM
PRESS 'ENTER'
COUPLE/UNCOUPLE EXTENDED CST (1-4):_
CURRENT EXTENDED CALL STATION ASSIGNMENT
INPUT 17-32 ECS: 1110 2220 XXXX 0000
PRESS '1' TO CONFIGURE EXTENDED CST
PRESS '2' TO CONFIGURE MASTER CST
* INSTALL MENU * scroll with 'ENTER'
PRESS 'C' TO CONFIGURE CALL STATIONS
Explanation
111
The key sets connected to inputs 17, 18 and 19 are functioning as
extensions of Call Station 1.
222
The key sets connected to inputs 21, 22, and 23 are functioning
as extensions of Call Station 2.
0
Nothing is assigned to inputs 24, 29, 30, 31 and 32.
X
The key sets connected to inputs25, 26, 27 and 28 are functioning
as extensions of the Master Call Station.
Summary of Contents for LBB 1330
Page 2: ......
Page 4: ...SM40 SOUND DISTRIBUTION SYSTEM ii This page has been left blank intentionally ...
Page 6: ...1 GENERAL INTRODUCTION AND OPERATING PRINCIPLES 1 ...
Page 8: ...1 GENERAL INTRODUCTION AND OPERATING PRINCIPLES 1 2 1 ...
Page 10: ...1 GENERAL INTRODUCTION AND OPERATING PRINCIPLES 1 4 1 ...
Page 12: ...2 UNPACKING AND INSTALLATION 2 ...
Page 16: ...3 SM 40 BASIC SYSTEM AND EXTENSION FRAME 3 ...
Page 18: ...3 SM 40 BASIC SYSTEM AND EXTENSION FRAME 3 2 3 ...
Page 20: ...3 SM 40 BASIC SYSTEM AND EXTENSION FRAME 3 4 3 ...
Page 21: ...3 SM 40 BASIC SYSTEM AND EXTENSION FRAME 3 5 3 ...
Page 22: ...4 OPERATING AND PROGRAMMING THE SM40 SYSTEM 4 ...
Page 60: ...5 SM40 MODULES 5 ...
Page 64: ...5 SM40 MODULES 5 4 5 ...
Page 66: ...5 SM40 MODULES 5 6 5 ...
Page 68: ...5 SM40 MODULES 5 8 5 ...
Page 70: ...5 SM40 MODULES 5 10 5 ...
Page 77: ...5 SM40 MODULES 5 17 5 This page has been left blank intentionally ...
Page 78: ...5 SM40 MODULES 5 18 5 b a c ...
Page 80: ...5 SM40 MODULES 5 20 5 IMPORTANT Ensure the interconnection cable is positioned correctly ...
Page 81: ...5 SM40 MODULES 5 21 5 ...
Page 82: ...5 SM40 MODULES 5 22 5 ...
Page 84: ...5 SM40 MODULES 5 24 5 ...
Page 85: ...5 SM40 MODULES 5 25 5 ...
Page 86: ...5 SM40 MODULES 5 26 5 ...
Page 88: ...5 SM40 MODULES 5 28 5 ...
Page 90: ...5 SM40 MODULES 5 30 5 ...
Page 92: ...5 SM40 MODULES 5 32 5 ...
Page 94: ...5 SM40 MODULES 5 34 5 ...
Page 96: ...5 SM40 MODULES 5 36 5 ...
Page 97: ...5 SM40 MODULES 5 37 5 ...
Page 98: ...5 SM40 MODULES 5 38 5 Surveillance Message Switch Card ...
Page 100: ...5 SM40 MODULES 5 40 5 ...
Page 101: ...5 SM40 MODULES 5 41 5 This page has been left blank intentionally ...
Page 106: ...5 SM40 MODULES 5 46 5 SM40 PHILIPS 6 7 8 9 10 1 2 3 4 5 CALL STATION LBB 9567 ...
Page 108: ...5 SM40 MODULES 5 48 5 ...
Page 110: ...5 SM40 MODULES 5 50 5 ...
Page 112: ...5 SM40 MODULES 5 52 5 ...
Page 113: ...5 SM40 MODULES 5 53 5 ...
Page 114: ...5 SM40 MODULES 5 54 5 ...
Page 115: ...5 SM40 MODULES 5 55 5 ...
Page 116: ...5 SM40 MODULES 5 56 5 ...
Page 117: ...5 SM40 MODULES 5 57 5 ...
Page 118: ...5 SM40 MODULES 5 58 5 ...
Page 120: ...5 SM40 MODULES 5 60 5 This page has been left blank intentionally ...
Page 135: ...6 REMOTE PROGRAMMING 1 O PROTOCOL 6 15 6 This page has been left blank intentionally ...
Page 139: ......