7. TECHNICAL DATA
7-1
7
7.1
GENERAL TECHNICAL SPECIFICATIONS
SUPPLY
Mains voltage
: 220 V (187 - 264 V)
110 V (90 - 132 V) (by jumper placement)
Frequency
: 47 to 440 Hz
Power consumption
: 160 VA (fully loaded frame)
Extension frame
: (depending on the number of cards)
Data retention time
: >30 days
Safety standard
: According to IEC 65
MECHANICAL
Dimensions (w x d x h)
- rack frame
: 483 x 376 x 133 (3HE)
- circuit cards
: 1.6 x 220 x 100 mm
Weight
- Distribution Basic system
: 6.5 kg
- Extension frame
: 5.5 kg
Terminations
- Termination boards
: screw connector blocks
ENVIRONMENTAL CONDITIONS
Temperature
: +5 to +55°C
7.2
CARD SUPPLY
+15V
45
45
75
105
80
15
130
65
50
290
1000
2000
-15V
35
35
75
105
80
130
60
50
245
1000
2000
+5V
140
140
10
10
–
–
–
125
25
345
4000
–
Distribution System Cards
Input Card
Signal Generator Card
Matrix Card
Control Relay Card
Tone Control Card
Call Station
Signal Processing Card
Automatic Volume Control Card
Digital Message Card
Distribution Basic System
without optional cards
max. available power:
Extension Frame
max. available power:
Typical supply currents (mA)
Summary of Contents for LBB 1330
Page 2: ......
Page 4: ...SM40 SOUND DISTRIBUTION SYSTEM ii This page has been left blank intentionally ...
Page 6: ...1 GENERAL INTRODUCTION AND OPERATING PRINCIPLES 1 ...
Page 8: ...1 GENERAL INTRODUCTION AND OPERATING PRINCIPLES 1 2 1 ...
Page 10: ...1 GENERAL INTRODUCTION AND OPERATING PRINCIPLES 1 4 1 ...
Page 12: ...2 UNPACKING AND INSTALLATION 2 ...
Page 16: ...3 SM 40 BASIC SYSTEM AND EXTENSION FRAME 3 ...
Page 18: ...3 SM 40 BASIC SYSTEM AND EXTENSION FRAME 3 2 3 ...
Page 20: ...3 SM 40 BASIC SYSTEM AND EXTENSION FRAME 3 4 3 ...
Page 21: ...3 SM 40 BASIC SYSTEM AND EXTENSION FRAME 3 5 3 ...
Page 22: ...4 OPERATING AND PROGRAMMING THE SM40 SYSTEM 4 ...
Page 60: ...5 SM40 MODULES 5 ...
Page 64: ...5 SM40 MODULES 5 4 5 ...
Page 66: ...5 SM40 MODULES 5 6 5 ...
Page 68: ...5 SM40 MODULES 5 8 5 ...
Page 70: ...5 SM40 MODULES 5 10 5 ...
Page 77: ...5 SM40 MODULES 5 17 5 This page has been left blank intentionally ...
Page 78: ...5 SM40 MODULES 5 18 5 b a c ...
Page 80: ...5 SM40 MODULES 5 20 5 IMPORTANT Ensure the interconnection cable is positioned correctly ...
Page 81: ...5 SM40 MODULES 5 21 5 ...
Page 82: ...5 SM40 MODULES 5 22 5 ...
Page 84: ...5 SM40 MODULES 5 24 5 ...
Page 85: ...5 SM40 MODULES 5 25 5 ...
Page 86: ...5 SM40 MODULES 5 26 5 ...
Page 88: ...5 SM40 MODULES 5 28 5 ...
Page 90: ...5 SM40 MODULES 5 30 5 ...
Page 92: ...5 SM40 MODULES 5 32 5 ...
Page 94: ...5 SM40 MODULES 5 34 5 ...
Page 96: ...5 SM40 MODULES 5 36 5 ...
Page 97: ...5 SM40 MODULES 5 37 5 ...
Page 98: ...5 SM40 MODULES 5 38 5 Surveillance Message Switch Card ...
Page 100: ...5 SM40 MODULES 5 40 5 ...
Page 101: ...5 SM40 MODULES 5 41 5 This page has been left blank intentionally ...
Page 106: ...5 SM40 MODULES 5 46 5 SM40 PHILIPS 6 7 8 9 10 1 2 3 4 5 CALL STATION LBB 9567 ...
Page 108: ...5 SM40 MODULES 5 48 5 ...
Page 110: ...5 SM40 MODULES 5 50 5 ...
Page 112: ...5 SM40 MODULES 5 52 5 ...
Page 113: ...5 SM40 MODULES 5 53 5 ...
Page 114: ...5 SM40 MODULES 5 54 5 ...
Page 115: ...5 SM40 MODULES 5 55 5 ...
Page 116: ...5 SM40 MODULES 5 56 5 ...
Page 117: ...5 SM40 MODULES 5 57 5 ...
Page 118: ...5 SM40 MODULES 5 58 5 ...
Page 120: ...5 SM40 MODULES 5 60 5 This page has been left blank intentionally ...
Page 135: ...6 REMOTE PROGRAMMING 1 O PROTOCOL 6 15 6 This page has been left blank intentionally ...
Page 139: ......