ABLE
2-11. V.25
BIS
M
ESSAGES
T
HE FOLLOWING MESSAGES WILL BE RETURNED
Call Failure Indication
CFI
Incoming Call
INC
Valid
VAL
Invalid
INV
Connection Established
CNX
T
ABLE
2-12. C
ALL
F
AILURE
R
EASONS
I
F A CALL FAILURE INDICATION IS RETURNED THE FOLLOWING REASONS MAY BE GIVEN
No answer
RT
Busy
ET
Hayes Commands Registers and Result Codes
The Hayes protocol allows the control of connections from the V.24 equipment in
exactly the same way as the V.25bis protocol.
Hayes also discriminates between the Command Mode and the Data Transfer
State. In a connection you can change back to the Command Mode with an
escape sequence (see Table 2-13).
The commands available in the ErgoLine D340 terminal are a subset of the Hayes
1200 Smart Modem commands.
T
ABLE
2-13. H
AYES
C
OMMANDS
N
OT ALL
H
AYES COMMANDS ARE USED
,
BUT THE FOLLOWING WILL BE ACCEPTED
AT
Command prefix must be given before all the
following commands (excluding A/)
A
Answer a data call
A/
Repeat last command (without AT)
B
Not used
C
Not used
D<number>
Dials the given number. If there is a semi-
colon
( ; ) after the command, other commands
may follow
E0
Local echo OFF
E1
Local echo ON
F
Not used
H0
Hang up
H1
Not used
H2
Not used
I0
Returns the software version number
I3
The Hayes parameters are reset to factory
default settings
L
Not used
M
Not used
O1, O2, O3
Return from Command Mode to Data
Transfer Mode
P
Not used
Summary of Contents for ErgoLine D310
Page 1: ...ErgoLine D330 D340 D310 D320 Customer Engineer Manual ...
Page 2: ...3513 302 60092 February 1999 ...
Page 6: ...ErgoLine D310 D320 Customer Engineer Manual ii ...
Page 20: ...ErgoLine D330 D340 Customer Engineer Manual Page 1 14 ...
Page 68: ...ErgoLine D330 D340 Customer Engineer Manual Page 3 4 ...
Page 74: ...ErgoLine D330 D340 Customer Engineer Manual Page 4 6 ...
Page 88: ...ErgoLine D310 320 Customer Engineer Manual Page 5 14 ...