ErgoLine D330/D340
Customer Engineer Manual
Page 2-17
All of the keys shown in Figures 2-2 and 2-4 are programmable. The downloadable
keys are shown in the non-shaded boxes. The function keys on the main terminal and
the DSS 1 keys are programmable on both levels. The numeric keys on the main
terminal are programmable on the second level only. The keys shown in the shaded
boxes (DSS 2 & DSS 3) are not downloadable in SSW 805 but are programmable on
both levels.
Facility Codes and Local Functions
To give the user full access to ISPBX and ErgoLine D330 and D340 facilities, it is
necessary to download facility codes. These facility codes are used for translation when a
function key has been programmed. Some codes need to be downloaded to allow
facilities to be presented in soft-key menus (for example, the automatic ring-back soft-key
is only presented when appropriate and when the automatic ring-back code has been
downloaded). It may also be required to download information to enable or disable certain
local ErgoLine terminal functions.
For the purposes of facility code and local function downloading, the same Operational
Maintenance commands are used as for function key downloading. This means that the
information to be downloaded is entered as if it were to be downloaded to function keys.
Information is downloaded to 'facility numbers' instead of 'function keys'. The facility
numbers have nothing to do with the actual keys and can be considered to be an 'address'
in the ErgoLine terminal memory. Facility codes are always downloaded to key level 0.
Table 2-3 provides a list of functions that can be downloaded and the Facility Number to
which the information is written in the ErgoLine terminal. Since the names used for
particular facility codes differ in various ISPBXs, their unique identity is given in the
column Result ID used when defining facility codes.
Local ErgoLine terminal functions are enabled or disabled by downloading a 0 or a 1. The
parameter name used in OM commands for the facility number is
KEY
.
Note
: For a number of functions it is also necessary that the user has the correct
facility class marks assigned in the SOPHO-iS. If no facility class mark is assigned
the user cannot use the facility.
T
ABLE
2-3. F
ACILITY
C
ODES AND
A
DDRESSES FOR FACILITY
C
ODE
D
OWNLOADING
INFORMATION TO BE STORED
NUMBER/FACILITY CODE
RESULT
ID
26
27
Executive/secretary absence
Executive/secretary absent
Executive/secretary present
40
41
28
29
Do-not-disturb
Activate do-not-disturb
Cancel do-not-disturb
66
67
30
31
Automatic ring-back
Activate automatic ring-back
cancel automatic ring-back
56
57
32
33
Follow-me
Activate follow-me
Cancel follow-me
27
32
34
Prepare
Prepare follow-me
28
35
Activate from dest
Activate follow-me from
destination
29
36
Deactivate from dest
Deactivate follow-me from
destination
30
37
Cancel
38
Auto answer
0 = No,
1 = Continuous
2 = 1hour
L
39
Microphone blocked enable
0 = No, 1 = Yes
L
40
One keystroke set-up
0 = No, 1 = Yes
L
41
Add-on
Activate 3-party call
55
FUNCTION
DOWNLOADED
FACILITY
NUMBER
Summary of Contents for ErgoLine D310
Page 1: ...ErgoLine D330 D340 D310 D320 Customer Engineer Manual ...
Page 2: ...3513 302 60092 February 1999 ...
Page 6: ...ErgoLine D310 D320 Customer Engineer Manual ii ...
Page 20: ...ErgoLine D330 D340 Customer Engineer Manual Page 1 14 ...
Page 68: ...ErgoLine D330 D340 Customer Engineer Manual Page 3 4 ...
Page 74: ...ErgoLine D330 D340 Customer Engineer Manual Page 4 6 ...
Page 88: ...ErgoLine D310 320 Customer Engineer Manual Page 5 14 ...