1-9-1
T1006EA
ELECTRICAL ADJUSTMENT INSTRUCTIONS
General Note:
"CBA" is abbreviation for "Circuit Board
Assembly."
NOTE:
Electrical adjustments are required after replacing
circuit components and certain mechanical parts.
It is important to perform these adjustments only
after all repairs and replacements have been com-
pleted.
Also, do not attempt these adjustments unless the
proper equipment is available.
Test Equipment Required
1. NTSC Pattern Generator (Color Bar W/White Win-
dow, Red Color, Dot Pattern, Gray Scale, Mono-
scope, Multi-Burst)
2. AC Milli Voltmeter (RMS)
3. Alignment Tape (VFMS0001H6), Blank Tape
4. DC Voltmeter
5. Oscilloscope: Dual-trace with 10:1 probe,
V-Range: 0.001~50V/Div,
F-Range: DC~AC-60MHz
6. Frequency Counter
7. Plastic Tip Driver
8. Color Analyzer
How to make service remote control
unit:
1. Prepare remote control unit (ID No. NE206UD, Part
No. 4835 218 37345). Remove 4 screws from the
back lid (Fig. 1-1).
2. Cut off pin 10 of the remote control microprocessor
and short circuit pins 10 and 17 of the microproces-
sor with a jumper wire
How to Set up the Service mode:
Service mode:
1. Use the service remote control unit.
2. Turn the power on. (Use main power on the TV
unit.)
3. To enter the TV mode, press "CH
o
/
p
" button on
the TV unit.
4. Press "DISC MENU" button on the service remote
control unit. Version of micro computer will display
on the CRT. (Ex: 057-001)
X-Ray Protection Test
X-Ray protection test should be done when replacing
any parts of this chassis.
1. Short both ends of R592 (on Sub CBA).
2. Confirm that the main power turns off.
3. If the main power does not turn off, then replace
the following parts (D591, Q591, R592, R593,
R594 and IC201).
4. Perform steps 1 to 3 again.
1. DC 114V (+B) Adjustment
Purpose:
To obtain correct operation.
Symptom of Misadjustment:
The picture is dark and
unit does not operate correctly.
Note:
D613 Cathode (+B), HEAT SINK, VR601 --- Main CBA
1. Connect the unit to AC Power Outlet.
2. Connect DC Volt Meter to D613 Cathode (+B) and
HEAT SINK (GND).
3. Adjust VR601 so that the voltage of D613 Cathode
(+B) b114
±
1.0V DC.
SCREW
Fig. 1-1
Remote control unit (Bottom)
Test point
Adj. Point
Mode
Input
D613 Cathode (+B),
HEAT SINK (GND)
VR601
---
-----
Tape
M. EQ.
Spec.
---
DC Voltmeter
+114
±
1.0V DC
Summary of Contents for 20MC4304
Page 5: ...1 1 1 TD901IB OPERATING CONTROLS AND FUNCTIONS ...
Page 6: ...1 1 2 TD901IB ...
Page 7: ...1 2 1 TD901IBR REMOTE CONTROL OPERATION ...
Page 8: ...1 2 2 TD901IBR ...
Page 12: ...1 3 4 TD901DC S 4 S 4 S 4 S 4 4 CRT Anode Cap CRT CBA Fig 3 ...
Page 77: ...1 9 3 TD901PEX S4 S1 X1 TAPE X9 X11 1 X8 X11 2 X25 X4 X2 X3 S3 S6 S7 S2 PACKING TAPE Packing ...
Page 95: ...1 6 1 T1006IB OPERATING CONTROLS AND FUNCTIONS ...
Page 96: ...1 6 2 T1006IB ...
Page 97: ...1 7 1 T1006IBR REMOTE CONTROL OPERATION ...
Page 98: ...1 7 2 T1006IBR ...
Page 149: ...R583 H Adjustment Sub CBA Top View TV VCR Section 1 12 41 1 12 42 BT1000F01021 A ...
Page 195: ...1 5 1 T1102IB OPERATING CONTROLS AND FUNCTIONS ...
Page 196: ...1 5 2 T1102IB ...
Page 197: ...1 5 3 T1102IB ...
Page 198: ...1 5 4 T1102IB ...
Page 294: ...2 4 9 N2466FTDA 43 41 42 L 13 Fig DM16 44 45 Slide P 9 Fig DM17 ...