1-7-2
T1102EA
2. Setting for CONTRAST, COLOR,
TINT, V-TINT and SHARP Data
Values
General
1. Enter the Service mode. (See page 1-7-1.)
2. Press [PICTURE] button on the service remote
control unit. Display changes “BRT,” “CNT,” “COL,”
“TNT,” “V-TNT,” and “SHP” cyclically when [PICTURE]
button is pressed.
CONTRAST (CNT)
1. Press [PICTURE] button on the service remote
control unit. Then select “CONTRAST (CNT)”
display.
2. Press [CH.
o
/
p
] buttons on the service remote
control unit so that the value of “CONTRAST
(CNT)” becomes 84.
COLOR (COL)
1. Press [PICTURE] button on the service remote
control unit. Then select “COLOR (COL)” display.
2. Press [CH.
o
/
p
] buttons on the service remote
control unit so that the value of “COLOR (COL)”
becomes 58.
TINT (TNT)
1. Press [PICTURE] button on the service remote
control unit. Then select “TINT (TNT)” display.
2. Press [CH.
o
/
p
] buttons on the service remote
control unit so that the value of “TINT (TNT)”
becomes 56.
V-TINT (V-TNT)
1. Press [PICTURE] button on the service remote
control unit. Then select “V-TINT (V-TNT)” display.
2. Press [CH.
o
/
p
] buttons on the service remote
control unit so that the value of “V-TINT (V-TNT)”
becomes 56.
SHARP (SHP)
1. Press [PICTURE] button on the service remote
control unit. Then select “SHARP (SHP)” display.
2. Press [CH.
o
/
p
] buttons on the service remote
control unit so that the value of “SHARP (SHP)”
becomes 46.
Note: BRIGHT
data value does not need to be
adjusted at this moment.
3. C-Trap Adjustment
Purpose:
To get minimum leakage of the color signal
carrier.
Symptom of Misadjustment:
If C-Trap Adjustment is
incorrect, stripes will appear on the screen.
Note:
TP1301(B-OUT) --- Main CBA
1. Connect oscilloscope to TP1301.
2. Input a color bar signal from RF input.
Enter the Service mode. (See page 1-7-1.)
3. Press [0] button on the remote control unit and
select C-TRAP mode. (Fig. 3)
4. Press [CH.
o
/
p
] buttons on the remote control
unit so that the carrier leakage B-Out (3.58 MHz)
value becomes minimum on the oscilloscope.
Test Point
Adj. Point
Mode
Input
TP1301
(B-OUT)
[CH.
o
/
p
]
buttons
---
Color Bar
Tape
M. EQ.
Spec.
---
Oscilloscope
Pattern Generator
---
Figure
Fig. 2
minimum
Summary of Contents for 20MC4304
Page 5: ...1 1 1 TD901IB OPERATING CONTROLS AND FUNCTIONS ...
Page 6: ...1 1 2 TD901IB ...
Page 7: ...1 2 1 TD901IBR REMOTE CONTROL OPERATION ...
Page 8: ...1 2 2 TD901IBR ...
Page 12: ...1 3 4 TD901DC S 4 S 4 S 4 S 4 4 CRT Anode Cap CRT CBA Fig 3 ...
Page 77: ...1 9 3 TD901PEX S4 S1 X1 TAPE X9 X11 1 X8 X11 2 X25 X4 X2 X3 S3 S6 S7 S2 PACKING TAPE Packing ...
Page 95: ...1 6 1 T1006IB OPERATING CONTROLS AND FUNCTIONS ...
Page 96: ...1 6 2 T1006IB ...
Page 97: ...1 7 1 T1006IBR REMOTE CONTROL OPERATION ...
Page 98: ...1 7 2 T1006IBR ...
Page 149: ...R583 H Adjustment Sub CBA Top View TV VCR Section 1 12 41 1 12 42 BT1000F01021 A ...
Page 195: ...1 5 1 T1102IB OPERATING CONTROLS AND FUNCTIONS ...
Page 196: ...1 5 2 T1102IB ...
Page 197: ...1 5 3 T1102IB ...
Page 198: ...1 5 4 T1102IB ...
Page 294: ...2 4 9 N2466FTDA 43 41 42 L 13 Fig DM16 44 45 Slide P 9 Fig DM17 ...