+B ADJ
VR2601
DVD-C
TP2204
WF18
DVD-Y
TP2203
WF17
WF19
PIN 6
OF CN2401
WF20
PIN 1
OF CN2401
Power Supply / AV CBA Top View < TV/VCR Section >
1-5-23
1-5-24
BTD850F01022A
BECAUSE A HOT CHASSIS GROUND IS PRESENT IN THE POWER
SUPPLY CIRCUIT, AN ISOLATION TRANSFORMER MUST BE USED.
ALSO, IN ORDER TO HAVE THE ABILITY TO INCREASE THE INPUT
SLOWLY, WHEN TROUBLESHOOTING THIS TYPE POWER SUPPLY
CIRCUIT, A VARIABLE ISOLATION TRANSFORMER IS REQUIRED.
NOTE :
The voltage for parts in hot circuit is measured
using hot GND as a common terminal.
CAUTION:
FOR CONTINUED PROTECTION AGAINST RISK
OF FIRE, REPLACE ONLY WITH SAME TYPE 4A, 125V FUSE.
ATTENTION:
UTILISER UN FUSIBLE DE RECHANGE DE
MÊME TYPE DE 4A, 125V.
4A 125V
CAUTION !
Fixed voltage ( or Auto voltage selectable ) power supply circuit is used in this unit.
If Main Fuse (F2601) is blown, check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
Summary of Contents for 20MC4304
Page 5: ...1 1 1 TD901IB OPERATING CONTROLS AND FUNCTIONS ...
Page 6: ...1 1 2 TD901IB ...
Page 7: ...1 2 1 TD901IBR REMOTE CONTROL OPERATION ...
Page 8: ...1 2 2 TD901IBR ...
Page 12: ...1 3 4 TD901DC S 4 S 4 S 4 S 4 4 CRT Anode Cap CRT CBA Fig 3 ...
Page 77: ...1 9 3 TD901PEX S4 S1 X1 TAPE X9 X11 1 X8 X11 2 X25 X4 X2 X3 S3 S6 S7 S2 PACKING TAPE Packing ...
Page 95: ...1 6 1 T1006IB OPERATING CONTROLS AND FUNCTIONS ...
Page 96: ...1 6 2 T1006IB ...
Page 97: ...1 7 1 T1006IBR REMOTE CONTROL OPERATION ...
Page 98: ...1 7 2 T1006IBR ...
Page 149: ...R583 H Adjustment Sub CBA Top View TV VCR Section 1 12 41 1 12 42 BT1000F01021 A ...
Page 195: ...1 5 1 T1102IB OPERATING CONTROLS AND FUNCTIONS ...
Page 196: ...1 5 2 T1102IB ...
Page 197: ...1 5 3 T1102IB ...
Page 198: ...1 5 4 T1102IB ...
Page 294: ...2 4 9 N2466FTDA 43 41 42 L 13 Fig DM16 44 45 Slide P 9 Fig DM17 ...