An NTC is used as a temperature sensor; in the event of overheating this reduces boiler
element power consumption.
The electronic system detects the current boiler temperature from the drop in voltage of the
sensor and adjusts it accordingly.
Heating element values and corresponding temperatures
: see table
4.6. Temperature sensor (adjustment)
Temp. (°C) R nom (k
Ω
)
Δ
R (+/- %)
20
61.465
8.6
50
17.599
5.9
75
7.214
4.1
80
6.121
3.7
85
5.213
3.4
90
4.459
3.1
100
3.3
2.5
125
1.653
3.9
150
0.893
5.1
4.5.
Single
microswitch
The gearmotor is powered by a direct current
motor that engages with the smaller double
toothed wheel using a worm screw. The
unit is mounted on the axle of the large
gear wheel and when a coffee is requested,
it moves from the standby position to the
dispensing position, and then back to the
standby position again.
- Standby position: 1
- Dispensing position: 2
2
1
06
Summary of Contents for Exprelia Series
Page 3: ...Saeco International Group Rev 00 June 2010 EXPRELIA CHAPTER 1 INTRODUCTION...
Page 8: ...Saeco International Group Rev 00 June 2010 EXPRELIA CHAPTER 2 TECHNICAL SPECIFICATIONS...
Page 18: ...Saeco International Group Rev 00 June 2010 EXPRELIA CHAPTER 4 OPERATING LOGIC...
Page 30: ...Saeco International Group Rev 00 June 2010 EXPRELIA CHAPTER 5 TROUBLESHOOTING...
Page 41: ...Saeco International Group Rev 00 June 2010 EXPRELIA CHAPTER 7 DISASSEMBLY...
Page 51: ...Saeco International Group Rev 00 June 2010 EXPRELIA CHAPTER 8 CHAPTER 8 NOTES NOTES...
Page 52: ...EXPRELIA 08 NOTES Saeco International Group Rev 00 June 2010 Page 01 01...
Page 54: ...EXPRELIA 09 WATER CIRCUIT DIAGRAM Saeco International Group Rev 00 June 2010 Page 01 01...
Page 56: ...EXPRELIA 10 WIRING DIAGRAM Saeco International Group Rev 00 June 2010 Page 01 01...