Battery/Tank Monitor BTM2
REV 1A - FEB 2022 - Software Version 1.xPage 24
"Out of sync"
The shunt has been restarted and the displayed capacity value does not yet
correspond to the true capacity level. Then the battery group connected to
the shunt must be fully charged with a charger so that the capacity display
can synchronise with the battery's state of charge. The message then goes
out automatically.
"Charge battery"
the battery capacity has fallen below the set warning threshold. In order to
achieve a long battery life, the charging process should be initiated at the
next opportunity.
"Battery empty"
The battery capacity has fallen below a maximum of 20% residual capacity
and must be recharged immediately to prevent harmful deep discharge.
"Battery deep discharged"
The
battery
is
completely discharged and all consumers must be
switched off and
charging must be initiated immediately to prevent
further damage to
the battery.
"Temperature"
the battery temperature is outside the permissible range
The
charging screen
shows the operating status of the active
philippi charger ACE. If the ACE charger is disconnected from
the mains or if no charger is connected, the screen is not
active and cannot be selected.
The green arrow shows the current charging current and the
charging voltage. The battery symbol shows the current
charging phase (strong charge / full charge / maintenance)
and the battery temperature. To the right of the battery, the
mains voltage measured by the charger and its frequency are displayed.
The side buttons have the following function:
LIMIT +/-:
To adapt the charging current to the battery system or a weakly fused shore connection,
the charging current can be adjusted in 10%. The minimum value is 40%.