0

Bit7: 

 Reserve.

12

PIR Re-
Detect 
Interval Time

6

1 ~ 60

In the normal mode, after the PIR 
motion detected, setting the re-
detect time. 10 seconds per tick, 
default tick is 6 (60 seconds).
Setting the suitable value to 
prevent received the trigger signal 
too frequently. Also can save the 
battery energy.
Notice: If this value bigger than the 
configuration setting NO. 13. There
is a period after the light turned off 
and the PIR not start detecting.

13

Turn Off Light
Time

6

1 ~ 60

After turn on the lighting, setting 
the delay time to turn off the 
lighting when the PIR motion is not 
detected. 10 seconds per tick, 
default tick is 6 (60 seconds).
0 means never send turn off light 
command.

14

Auto Report 
Battery Time

12 0 ~ 127

The interval time for auto report the
battery level.
0 means turn off auto report 
battery.
The default value is 12. The tick 
time can setting by the 
configuration No.17.

15 Auto Report 

LightSensor 
Time

12 0 ~ 127 The interval time for auto report the

illumination.
0 means turn off auto report 

N

O.

Name

Def

.

Valid

Description

illumination.
The default value is 12. The tick 
time can setting by the 
configuration No.17.

16

Auto Report 
Temperature 
Time

12 0 ~ 127

The interval time for auto report the
temperature.
0 means turn off auto report 
temperature.
The default value is 12. The tick 
time can setting by the 
configuration No.17.

17

Auto Report 
Tick Interval

30

0 ~

0xFF

The interval time for auto report 
each tick. Setting this configuration 
will effect configuration No.14, 
No.15 and No.16.
The unit is 1 minute.
Caution1: Setting to 0 means turn 
off all auto report function.
Caution2: The value is unsigned 
byte, the range is from 0x00 ~ 
0xFF.

18 Temperature 

Differential 
Report

1

0 ~ 127 The temperature differential to 

report.
0 means turn off this function. 
The unit is Fahrenheit.
Enable this function the device will 
detect every minutes.
And when the temperature is over 
140 degree Fahrenheit, it will 
continue report.
Enable this functionality will cause 

8

Summary of Contents for PST07

Page 1: ...eTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Add to Remove from Z WaveTM Network There are two tamper keys in the device one is in the back side another is in the front side Both of them can add remove reset or association from Z WaveTM network The table below lists an operation summary of basic Z Wave fu...

Page 2: ...val minimum setting is 30 minutes and maximum setting is 120 hours And the interval step is 30 minutes If the user want to wake up the device immediately please remove the front cover and press the tamper key once The device will wake up 10 seconds Z WaveTM Message Report When the PIR motion triggered the device will report the trigger event and also report the battery status temperature and illum...

Page 3: ...NO 14 Low battery report When the battery level is too low every 30 minutes will report once LightSensor level report Every 6 hours report once in default It could be changed by setting the configuration NO 15 Temperature report Every 6 hours report once in default It could be changed by setting the configuration NO 16 Notice The configuration NO 14 15 and 16 could be setting to zero to disable th...

Page 4: ...D will flash once But in the Test Mode the LED also will light ON one second When the event triggered the device will emit the signal to turn ON the lighting equipment those nodes are in the group 2 And delay a while to turn OFF the lighting equipment The delay time is setting by the configuration NO 13 The PIR motion re detected interval in the Test Mode fixed to 10 seconds In the Normal Mode it ...

Page 5: ...guration the data size is 1 The configuration mark with star means after the remove the setting still keep don t reset to factory default Unless the user execute the RESET procedure The reserve bit or not supported bit is allowed any value but no effect 5 ...

Page 6: ...illumination detected function And never turn on the light 1 means darkest 100Lux 99 means brightest 100 means turn off illumination N O Name Def Valid Description detected function And always turn on the light Notice In none test mode only the value in 1 to 99 will enable the illumination detected function and update the illumination value 5 LightSensor Threshold line 2 2 1 100 0 means turn off i...

Page 7: ...ve 0 Bit4 Reserve 0 Bit5 Reserve 0 Bit6 Reserve 0 Bit7 Reserve 10 Mult Sensor Function Switch 0 All Multisensor function switch Using bit to control Caution The value is unsigned N O Name Def Valid Description byte the range is from 0x00 0xFF 0 Bit0 Reserve 0 Bit1 Disable PIR integrate Illumination to turn ON the lighting nodes in the association group 2 1 Disable 0 Enable 0 Bit2 Reserve 0 Bit3 Re...

Page 8: ...figuration No 17 15 Auto Report LightSensor Time 12 0 127 The interval time for auto report the illumination 0 means turn off auto report N O Name Def Valid Description illumination The default value is 12 The tick time can setting by the configuration No 17 16 Auto Report Temperature Time 12 0 127 The interval time for auto report the temperature 0 means turn off auto report temperature The defau...

Page 9: ...C 24 Temperature Threshold line 5 40 20 50C Temperature difference return The default is 40 degrees C 25 PIR Trigger Mode 1 1 3 PIR Trigger Mode Mode1 Normal Mode2 DayTime N O Name Def Valid Description Mode3 AtNight 26 PIR NightLine 1 1 100 PIR night line Lux conditions LightSensor determines whether the level is night Unit 100Lux Z Wave Supported Command Class Command Class Version Required Secu...

Page 10: ... recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Philio Technology Corporation 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan R O C www philio tech com FCC int...

Page 11: ...hanges or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Warning Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for info...

Reviews: