0
Bit7:
Reserve.
12
PIR Re-
Detect
Interval Time
6
1 ~ 60
In the normal mode, after the PIR
motion detected, setting the re-
detect time. 10 seconds per tick,
default tick is 6 (60 seconds).
Setting the suitable value to
prevent received the trigger signal
too frequently. Also can save the
battery energy.
Notice: If this value bigger than the
configuration setting NO. 13. There
is a period after the light turned off
and the PIR not start detecting.
13
Turn Off Light
Time
6
1 ~ 60
After turn on the lighting, setting
the delay time to turn off the
lighting when the PIR motion is not
detected. 10 seconds per tick,
default tick is 6 (60 seconds).
0 means never send turn off light
command.
14
Auto Report
Battery Time
12 0 ~ 127
The interval time for auto report the
battery level.
0 means turn off auto report
battery.
The default value is 12. The tick
time can setting by the
configuration No.17.
15 Auto Report
LightSensor
Time
12 0 ~ 127 The interval time for auto report the
illumination.
0 means turn off auto report
N
O.
Name
Def
.
Valid
Description
illumination.
The default value is 12. The tick
time can setting by the
configuration No.17.
16
Auto Report
Temperature
Time
12 0 ~ 127
The interval time for auto report the
temperature.
0 means turn off auto report
temperature.
The default value is 12. The tick
time can setting by the
configuration No.17.
17
Auto Report
Tick Interval
30
0 ~
0xFF
The interval time for auto report
each tick. Setting this configuration
will effect configuration No.14,
No.15 and No.16.
The unit is 1 minute.
Caution1: Setting to 0 means turn
off all auto report function.
Caution2: The value is unsigned
byte, the range is from 0x00 ~
0xFF.
18 Temperature
Differential
Report
1
0 ~ 127 The temperature differential to
report.
0 means turn off this function.
The unit is Fahrenheit.
Enable this function the device will
detect every minutes.
And when the temperature is over
140 degree Fahrenheit, it will
continue report.
Enable this functionality will cause
8