background image

N

O.

Name

Def

.

Valid

Description

1

Basic Set 
Level

0x

FF

All

Setting the BASIC command value 
to turn on the light. The 0xFF(-1) 
means turn on the light. For 
dimmer equipment 1 to 100 means 
the light strength.
0 means turn off the light.

Caution

: The value is unsigned 

byte, the range is from 0x00 ~ 
0xFF.

3

(*)

PIR 
Sensitivity

80

0 ~ 99

PIR sensitivity settings.
0 means disable the PIR motion.
1 means the lowest sensitivity,
99 means the highest sensitivity.
High sensitivity means can 
detected long distance, but if there 
is more noise signal in the 
environment, it will re-trigger too 
frequency.

4 LightSensor 

Threshold 
line 1

1

1 ~ 100 Setting the illumination threshold to

turn on the light. When the event 
triggered and the environment 
illumination lower then the 
threshold, the device will turn on 
the light.
0 means turn off illumination 
detected function. And never turn 
on the light.
1 means darkest. (100Lux)
99 means brightest.
100 means turn off illumination 

N

O.

Name

Def

.

Valid

Description

detected function. And always turn 
on the light.

Notice:

 In none test mode, only the

value in 1 to 99 will enable the 
illumination detected function and 
update the illumination value.

5

LightSensor 
Threshold 
line 2

2

1 ~ 100

0 means turn off illumination 
detected function. And never turn 
on the light.
1 means darkest. (200Lux)
99 means brightest.
100 means turn off illumination 
detected function. And always turn 
on the light.

6

LightSensor 
Threshold 
line 3

3

1 ~ 100

0 means turn off illumination 
detected function. And never turn 
on the light.
1 means darkest. (300Lux)
99 means brightest.
100 means turn off illumination 
detected function. And always turn 
on the light.

7 LightSensor 

Threshold 
line 4

4

1 ~ 100 0 means turn off illumination 

detected function. And never turn 
on the light.
1 means darkest. (400Lux)
99 means brightest.
100 means turn off illumination 

6

Summary of Contents for PST07

Page 1: ...eTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Add to Remove from Z WaveTM Network There are two tamper keys in the device one is in the back side another is in the front side Both of them can add remove reset or association from Z WaveTM network The table below lists an operation summary of basic Z Wave fu...

Page 2: ...val minimum setting is 30 minutes and maximum setting is 120 hours And the interval step is 30 minutes If the user want to wake up the device immediately please remove the front cover and press the tamper key once The device will wake up 10 seconds Z WaveTM Message Report When the PIR motion triggered the device will report the trigger event and also report the battery status temperature and illum...

Page 3: ...NO 14 Low battery report When the battery level is too low every 30 minutes will report once LightSensor level report Every 6 hours report once in default It could be changed by setting the configuration NO 15 Temperature report Every 6 hours report once in default It could be changed by setting the configuration NO 16 Notice The configuration NO 14 15 and 16 could be setting to zero to disable th...

Page 4: ...D will flash once But in the Test Mode the LED also will light ON one second When the event triggered the device will emit the signal to turn ON the lighting equipment those nodes are in the group 2 And delay a while to turn OFF the lighting equipment The delay time is setting by the configuration NO 13 The PIR motion re detected interval in the Test Mode fixed to 10 seconds In the Normal Mode it ...

Page 5: ...guration the data size is 1 The configuration mark with star means after the remove the setting still keep don t reset to factory default Unless the user execute the RESET procedure The reserve bit or not supported bit is allowed any value but no effect 5 ...

Page 6: ...illumination detected function And never turn on the light 1 means darkest 100Lux 99 means brightest 100 means turn off illumination N O Name Def Valid Description detected function And always turn on the light Notice In none test mode only the value in 1 to 99 will enable the illumination detected function and update the illumination value 5 LightSensor Threshold line 2 2 1 100 0 means turn off i...

Page 7: ...ve 0 Bit4 Reserve 0 Bit5 Reserve 0 Bit6 Reserve 0 Bit7 Reserve 10 Mult Sensor Function Switch 0 All Multisensor function switch Using bit to control Caution The value is unsigned N O Name Def Valid Description byte the range is from 0x00 0xFF 0 Bit0 Reserve 0 Bit1 Disable PIR integrate Illumination to turn ON the lighting nodes in the association group 2 1 Disable 0 Enable 0 Bit2 Reserve 0 Bit3 Re...

Page 8: ...figuration No 17 15 Auto Report LightSensor Time 12 0 127 The interval time for auto report the illumination 0 means turn off auto report N O Name Def Valid Description illumination The default value is 12 The tick time can setting by the configuration No 17 16 Auto Report Temperature Time 12 0 127 The interval time for auto report the temperature 0 means turn off auto report temperature The defau...

Page 9: ...C 24 Temperature Threshold line 5 40 20 50C Temperature difference return The default is 40 degrees C 25 PIR Trigger Mode 1 1 3 PIR Trigger Mode Mode1 Normal Mode2 DayTime N O Name Def Valid Description Mode3 AtNight 26 PIR NightLine 1 1 100 PIR night line Lux conditions LightSensor determines whether the level is night Unit 100Lux Z Wave Supported Command Class Command Class Version Required Secu...

Page 10: ... recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Philio Technology Corporation 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan R O C www philio tech com FCC int...

Page 11: ...hanges or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Warning Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for info...