Reset
Notice: Use this procedure only in the event that
the primary controller is lost or otherwise
inoperable.
1. Pressing button four times and keep about 5
seconds.
2. IDs are excluded and all settings will reset to
factory default.
Associatio
n
1.
Have Z-Wave
TM
Controller entered association
mode.
2. Pressing tamper key three times within 1.5 seconds
to enter the association mode.
Note: The device support 2 groups. The group 1 is for
receiving the report message, like triggered event,
temperature, illumination etc. The group 2 is for light
control, the device will send the “Basic Set” command
to this group. And each group support 8 nodes
maximum.
•
Failed or success in add/remove the node ID can be viewed
from Z-Wave
TM
Controller.
Notice 1:
Always RESET a Z-Wave
TM
device before trying to add it to a
Z-Wave
TM
network
Z-Wave
TM
Notification
After the device adding to the network, it will wake-up once per day in
default. When it wake-up it will broadcast the “Wake Up Notification”
message to the network, and wake-up 10 seconds for receive the
setting commands.
The wake-up interval minimum setting is 30 minutes, and maximum
setting is 120 hours. And the interval step is 30 minutes.
If the user want to wake-up the device immediately, please remove the
front cover, and press the tamper key once. The device will wake-up 10
seconds.
Z-Wave
TM
Message Report
When the PIR motion triggered, the device will report the trigger event
and also report the battery status, temperature and illumination level.
* Motion Report:
When the PIR motion detected, the device will unsolicited to send the
report to the nodes in the group 1.
Notification Report (V8)
Notification Type: Home Security (0x07)
Event: Motion Detection, Unknown Location (0x08)
* Tamper Report:
Both the 2 tamper keys are pressed over 5 seconds. The device will
into the alarm state. In that state, if any one of the tamper keys be
released, the device will unsolicited to send the report to the nodes in
the group 1.
Notification Report (V8)
Notification Type: Home Security (0x07)
Event: Tampering. Product covering removed (0x03)
* Temperature Report:
When the PIR motion detected state changed, the device will
unsolicited to send the “Sensor Multilevel Report” to the nodes in the
group 1.
Sensor Type: Temperature (0x01)
*** Temperature differential report ***
This function default is enabled, to disable this function by setting the
2