The Variable Temperature Control (VTC-1D) automatically controls the temperature in a room by adjusting 
the speed of variable speed fans. 

When the temperature is at the temperature set point, the VTC-1D operates the fans at the idle speed setting. 
When the temperature exceeds the set point, the VTC-1D increases the speed. When the temperature drops 
below the set point, the VTC-1D shuts off the fans (in shut-off mode) or operates the fans at idle speed (idle 
mode). 

 

 

Features 

‹

 

One variable speed output 

‹

 

Automatic shut-off and idle modes 

‹

 

Adjustable off set-back for shut-off mode 

‹

 

Adjustable idle speed for idle mode 

‹

 

Adjustable temperature set point 

‹

 

Adjustable temperature differential 

‹

 

Three-second full-power-turn-on to minimize 
fan ice-up 

‹

 

Two-digit LED display 

‹

 

Fahrenheit and Celsius display 

‹

 

Error code display for troubleshooting 

‹

 

Overload protection fuse 

‹

 

Six-foot temperature probe, extendable to 500 
feet 

‹

 

Rugged enclosure (corrosion resistant, water 
resistant, and fire retardant) 

‹

 

CSA approval 

‹

 

Two-year limited warranty 

 

 

Electrical ratings 

‹

 

Input:  

115/230 VAC, 50/60 Hz 

‹

 

Variable stage:   10 A at 120/230 VAC, general-purpose (resistive) 
 

7 FLA at 120/230 VAC, PSC motor  

 

1/2 HP at 120 VAC, 1 HP at 230 VAC, PSC motor 

‹

 

Fuse:  

15 A, 250 VAC ABC-type ceramic 

 

 

The FLA (full load ampere) rating accounts for the increase in motor current draw 
when the motor operates at less than full speed. Make sure the motor/equipment 

connected to the variable stage does not draw more than 7 FLA. 

Summary of Contents for VTC-1D

Page 1: ...idle mode Adjustable temperature set point Adjustable temperature differential Three second full power turn on to minimize fan ice up Two digit LED display Fahrenheit and Celsius display Error code di...

Page 2: ...the enclosure Use watertight strain reliefs or conduit connectors at all cable entry points Before removing electrical knockouts remove the cover to prevent damaging the control Do not make additiona...

Page 3: ...idelines and the guidelines below when extending cables Use two wire 18 AWG jacketed cable Phason recommends Belden 9408 Alpha 5052 or an equivalent Extension cable is also available from Phason For m...

Page 4: ...ower system is 60Hz 4 The display flashes between the temperature display and PF The pf indicates a power interruption has occurred To clear the PF click the switch to the right The control is now in...

Page 5: ...99 N A External knob Temperature differential di 1 to 20 F 0 6 to 12 C 6 F Internal trimmer Off set back oS 0 to 16 F 0 to 9 C 5 F Internal trimmer F or C ambient temp F C 22 to 99 F 30 to 38 C F Int...

Page 6: ...b to the desired setting while holding the switch to the right The temperature set point can be between 32 and 98 F 0 and 38 C 3 Release the switch You must hold the switch to the right while turning...

Page 7: ...factor calculate the correction as follows 1 Set the idle speed properly For more information see Setting minimum ventilation in idle mode on page 8 2 Set the differential to 10 F with the internal tr...

Page 8: ...g the voltage If you are unsure see your fan dealer for the minimum idle voltage for your fan motor 8 Press and hold the switch to the right 9 Turn the Temperature knob to the desired temperature set...

Page 9: ...ture set point When the temperature is between 80 F and 86 F the differential temperature fan speed changes proportionally with the temperature If the temperature increases fan speed increases If the...

Page 10: ...mperature fan speed changes proportionally with the temperature If the temperature increases fan speed increases If the temperature decreases fan speed decreases When the temperature is at or above 86...

Page 11: ...t that is labelled as non corrosive electronics grade or neutral cure such as GE Silicone RTV6780B RTV 142 or RTV 162 Do not use a sealant that is labelled as acetic acid cure or acetoxy cure These se...

Page 12: ...rovide proof of purchase upon request All transportation charges for products submitted for warranty must be paid by the purchaser Except to the extent prohibited by applicable law no other warranties...

Reviews: