Maintaining the VTC-1D
Proper care and maintenance will help your VTC-1D last longer. To prevent damage to the control, perform
the following steps after the first two weeks of operation, and once a year after that.
1.
Switch off the power to the control.
2.
Remove the cover and check inside for moisture. If there is any moisture, wipe it away using a dry cloth.
3.
Check all cable entry points to make sure they are properly sealed. If they are not properly sealed, apply
silicone sealant around the entry points.
If you need to seal the enclosure, use a sealant that is labelled as ‘non-corrosive’,
‘electronics grade’, or ‘neutral cure’, such as GE Silicone RTV6780B, RTV 142, or
RTV 162.
Do not
use a sealant that is labelled as ‘acetic acid cure’ or ‘acetoxy cure’. These
sealants release acetic acid while curing, which can damage the control and will
void the warranty.
4.
Check all wires to make sure they are properly connected and that they are in good condition.
5.
Fasten the cover to the enclosure and then switch on the power to the control.
Cleaning the VTC-1D
To clean the VTC-1D, wipe the surface with a damp cloth.
Be careful when washing the room using a high-pressure washer. DO NOT spray
the control using a high-pressure washer, this can damage the control and will void
the warranty.
Evidence of moisture damage inside the control will void the warranty.