FT Silomat E 140
(VAE)
Operating Instructions
05.2008
Knauf PFT GmbH & Co. KG
15
Depressurizing the system
¾
Turn the main reversing switch (8) to the
position “0”.
¾
By turning the hand wheel (9), the locking flap
of the motor and drive is opened slightly so
that the pressure can escape into the silo /
container.
¾
Close the locking flap again.
WARNING!
In accordance with the accident prevention regulations of the Builder’s Guild,
all personnel clearing blockages should wear safety goggles and should
position themselves in such a way so that they cannot be hit by discharged
material. No other persons should be in the vicinity.
Clearing hose blockages
¾
Depressurize and de-energize the conveying system (see above).
¾
Disconnect conveying hoses in the vicinity of the blocked part.
¾
Shake the hose and knock the coupling against a soft surface (wood or
something similar) to loosen the obstructing material and remove it from
the hose.
¾
Then reconnect the conveying hoses and make the system ready for
operation.
¾
Start the system at the position
“HAND”
(5) and let the compressor run
until the hose is blown free.
¾
Then switch back to automatic operation (5).
Cleaning emulgator filters: The pressure display is at “0”
WARNING!
Do not clean the system with a steam sprayer or high-pressure cleaner.
8
9
5