FT Silomat E 140
(VAE)
Operating Instructions
05.2008
Knauf PFT GmbH & Co. KG
13
Plug the vibrator cable from the silo / container into the CEE panel-mounted
socket 4 x 16 A 6 h red.
Now connect the SILOMAT system
to a worksite switchgear assembly with a power cable 5 x 4 mm² (PFT
item no. 20 42 39 00 or 20 42 39 20) in accordance with VDE with 30 mA
earth leakage circuit breakers that conform to regulations.
Open the silo outlet flap.
Main reversing switch (8) on.
Turn the hand automatic switch (5) to the automatic position and press the
green operating switch “ON” (6).
As soon as the level sensor reports “EMPTY”:
¾
The locking flap opens, and during the set filling time
¾
the conveying container is filled with approx. 62 l dry material.
¾
The vibrator runs at the same time if the cable connection is established.
¾
The locking flap closes after the filling time has elapsed and the compressor starts.
¾
After the conveying time has elapsed and when the pressure has dropped to below 0.6 bar (if the
hose is empty) it shuts down by itself.
¾
The system waits for a new signal to repeat the conveying cycle for the fully automatic supply of the
cleaning machine.
5
6
8