Mixing pump RITMO L plus FC-230V Overview – Operation
Remote control
2020-11-09
43
45.4 Switching off the air compressor
Fig. 84: Air compressor
1. Disconnect the connector plug from the air compressor (1).
2. Open air valve on the spray gun so that the residual pressure
can escape.
DANGER!
Danger of injury due to leaking mortar!
Escaping mortar can lead to injuries to the eyes
and face.
Beware of residual pressure.
46 Remote control
46.1 Using the remote control without spray gun
Fig. 85: Remote control
NOTE!
It is also possible to operate the machine without
compressed air for pouring liquid filler or for
working with a glue gun. Disconnect the connector
plug from the air compressor and work without
spray gun for this. The machine is then switched
on and off via an optional remove control cable.
1. Disconnect the connector plug for the switching off the pressure
from the control box and connect remote control (1).
2. The RITMO can be switched on or off via the remote control.
47 Working with pastes
47.1 Recommended accessories for pastes
Fig. 86: Air compressor
Item number: 00 23 31 74
Description: Air compressor LK 402 IV
1
1