Warning, danger of burns from touching hot
parts.
Warning, danger of personal injury.
Caution, danger of damage to the pump or to
the system.
Warning, danger of injury from rotating parts.
Please note, attention to particularly important
information on the product, handling the
product or to a particular part of the
documentation.
☞
PLEASE NOTE
WARNING
CAUTION
WARNING
WARNING
☞
Read and follow all instructions in this manual.
☞
Inform yourself regarding:
– Hazards which can be caused by the pump;
– Hazards which can be caused by your system.
– Hazards which can be caused by the media being
pumped.
☞
Avoid exposing any part of the body to vacuum.
☞
Observe the safety and accident prevention regulations.
☞
Regularly check that all accident prevention measures are
being complied with.
☞
Do not operate the turbopump with open high vacuum
flange.
☞
Do not carry out any unauthorised conversions or
alterations to the turbopump with TC 600.
☞
When returning the turbopump observe the shipping
instructions.
☞
The turbopump must be anchored in accordance with the
installation instructions.
☞
Do not disconnect the plug between the TC 600 and
accessory components during operations.
☞
Disconnect the voltage supply for the TC 600 before
opening the turbopump.
☞
When working on the turbopump, the high vacuum flange
should only be opened once the rotor is at rest.
☞
When using sealing gas, the pressure in the hose connec-
tion should be limited to 2 bar via the overpressure valve.
☞
If a heater is in use temperatures of up to 120 °C can be
present in the area of the high vacuum flange. Take care to
avoid burns !
☞
During operations, temperatures of up to 65 °C can arise in
the lower part of the turbopump. Take care to avoid burns !
☞
Keep leads and cables well away from hot
surfaces ( > 70 °C).
☞
Operate the turbopump with TC 600 only in conjunction
with the relevant power supply (accessory).
☞
Without the cover plate for the TC 600 the unit has been
accredited protection class IP 30. When the unit is
operated in environments which require other protection
classes, the necessary measures must be taken. When the
turbopump is water cooled a cover plate for the TC 600
must be installed by an electrical specialist, in order to
attain protection class IP 54 (Sec. 11 Accessories).
☞
The mains connection must be subject to a safe
connection to the PE (protection class 1).
☞
If the turbopump and the TC 600 are operated
independently of each other (only permissible with the
agreement of the manufacturer) the turbopump must be
connected to the PE.
☞
The turbopump and the TC 600 must only be
disconnected from each other when the turbopump is
completely at rest and the TCP 600 has been disconnected
from the power supply.
☞
The cause of any operating voltage leakage to earth
(red LED flashes) must be eliminated to avoid the danger of an
electric shock.
☞
The housing screws do not loosen, pull tight,
remove or replace, since otherwise the guarantee for the
security of the turbopump expires.
Modifications reserved.
1. Safety Instructions
1.1. For Your Orientation
Instruction in the text
➡
Working instruction:
here, you have to do something.
Symbols used
The following symbols are used throughout in all illustrations.
High vacuum flange
Fore-vacuum flange
Venting connection
Air cooling
Electric connection
Sealing gas connection
Abbreviations used
DCU = Display and operating unit
HPU = Display and operating unit
TC
= Electronic drive unit, turbopump
TPS = Power supply
Position numbers
The same pump and accessory parts have the same position
numbers in all illustrations.
1.2. Pictogram Definitions