Required tools
● Allen key
● Calibrated torque wrench (tightening factor ≤ 1.6)
Procedure
1. Loosen and remove the fore-vacuum line from the turbopump.
2. Make sure not to kink or damage the fore-vacuum hose.
3. Unscrew all 4 fixing screws and washers from the mounting plate.
– Fixing screw tightening torque for subsequent reassembly:
10 Nm
.
4. Remove the entire turbopump and mounting plate from frame.
Service turbopump
The opening in the mounting plate makes it easy for customers to perform mainte-
nance work on the turbo pump (e.g. change the lubricant reservoir).
Maintenance
40/60