40
Adjustment
Group
Gruppe
Parameter
Parameter
Description
Bedeutung
Setting
range
Set value
600
611
Automatic clamp opening off
With this function the automatic ope-
ning of the clamp after thread trim-
ming can be switched off. After the
machine has been switched off, the
automatic clamp opening function
is always activated.
ON - OFF
OFF
612
Test function continuous start
ON - OFF
OFF
800
The function groups and the functions
Programming the Function Keys
P, P1-
P8
and
C1-C3
can be released for mani-
pulation (ON) or locked (OFF). If a func-
tion group is suppressed, its parame-
ters cannot be changed until a valid ac-
cess code has been entered. Once a
valid access code has been entered,
the suppression is cancelled until the
machine is switched off.
801
Right of access function group 000
ON - OFF
ON
802
Right of access function group
100
ON - OFF
ON
807
Right of access function group
600
ON - OFF
OFF
808
Right of access function group
700
ON - OFF
OFF
809
Right of access function group
800
ON - OFF
OFF
810
Right of access to keys "P"
,
"
P1" - "P8"
and "
C1" - "C3"
ON - OFF
ON
811
Access code
This parameter is used to alter the ac-
cess code. Upon delivery the
machine is set with the access code
"3371".
3371
1
.32
Error messages on the display
Following error messages are shown on the control panel display
ERROR:
1
Processor error STACK_OVERFLOW
ERROR:
2
Processor error STACK_UNDERFLOW
ERROR:
3
Processor error UNDEF_OPCODE
ERROR:
4
Processor error PROTECTION_FAULT