Adjustment
15
Fig. 1 - 09
1
.13
Work clamp height
Requirement
1. The work clamp should be
13
mm
above the upper edge of the needle plate.
2. Both halves of the work clamp should be parallel to each other.
●
Turn lever
1
(nut
2
and screw
3
) in accordance with
requirement
1
.
●
Move lift plate
4
(screws
5
) in accordance with
requirement
2
.
After aligning the work clamp, it is imperative to check the position of the
thread wiper, see Chapter
1
.
14
. Position of the thread wiper! Danger of
needle breakage!
1
2
5
4
1
3
13 mm