35
Adjustment
Group
Gruppe
Parameter
Parameter
Description
Bedeutung
Setting
range
Set value
000
013
NIS "needle in material" [°]
This parameter is used to set the NIS
signal. If the function is executed, the
position can be entered by turning the
balance wheel. If the position is alte-
red, the result is a change in the point
of time when the carriage is moved.
The access code is necessary for this
adjustment.
65 -166
107
014
Thread trimming speed [min
-1
]
This parameter is used to fi x the
speed for thread trimming.
100 - 700
300
015
Reduced current for stepping motors
The reduction function of the holding
current at rest with closed work clamp
is switched on or off.
ON - OFF
ON
016
Key tone
The key tone, as reaction to a key on
the control panel being pressed, is
switched on or off. The double tone
for incorrect inputs always remains
switched on.
ON - OFF
ON
017
Clamp solenoid Operating time [10 ms]
The time, for which the solenoid is un-
der full current, is entered.
5
- 100
10
018
Clamp solenoid duty-cycle [%]
At the end of the clamp solenoid ope-
rating time (Parameter "
017")
the so-
lenoid is clocked. The relationship bet-
ween duration of operation and non-
operation is entered here.
5
- 100
20
019
Thread trimming solenoid operating
time [10 ms]
The time, for which the solenoid is un-
der full current, is entered.
5
- 100
25
020
Thread trimming solenoid duty-cycle
At present without a function
5
- 100
100