37
Adjustment
Group
Gruppe
Parameter
Parameter
Description
Bedeutung
Setting
range
Set value
600
601
Display inputs
With this function the digital inputs
can be checked. "IN" shows the input
numbers (1 - 16). Under "VAL" the re-
spective switch status is displayed.
IN VAL
1
IN1,
programmable input 1
2
IN2,
programmable input 2
3
E3,
work clamp raised
4
5
6
7
8
9
10
11
12
13
14
15
16
602
Display special inputs
With this function it is possible to
check the special inputs pedal,
reference X (SM
1)
and reference Y
(SM
2).
"IN" shows the inputs (PED,
REFX, REFY). Under "VAL" the
respective switch status is displayed.
IN VAL
PED Pedal (speed control unit
-
1; 0;
+
1; 2)
REFX Reference input X
REFY Reference input Y