38
Adjustment
Group
Gruppe
Parameter
Parameter
Description
Bedeutung
Setting
range
Set value
600
603
Connect outputs
With this function the outlets can be
connected. "OUT" shows the outlet
selected (
1-16).
Under "VAL" the
selected output is set (S) with the
plus/minus key (+), and reset (R) with
the plus/minus key. Interlocks are
checked. Non-assigned outlets are not
connected.
OUT VAL
1
S/R
Solenoid for work
clamp
open
2
S/R
3
S/R Solenoid
for
thread
trimming
4
S/R
5
S/R
6
S/R Program
outlet
7
S/R Program
outlet
8
S/R
9
S/R
10
S/R
11
S/R
12
S/R
13
S/R
14
S/R
15
S/R
16
S/R
604
Move stepping motors
The stepping motors SM1 (X-axis) and
SM2 (Y-axis) are moved individually
with the respective plus/minus keys.
Interlocks are not checked.
605
Turn sewing motor
The sewing motor can be operated
with a selectable set speed by pres-
sing the pedal. After the sewing motor
has been started, the current speed is
also displayed.
500 -2700
500