CIRCULAR SAW TLC 800/900/1000/1200 vertical
46
0 2 0
B
0 0 2
1
Chapter 13
(control unity for cut)
USE OF THE MACHINE
CALIBRATION IN THE CASE OF NECESSITY
Insertion of the parameter LT
N.B. This calibration has been executed in
the factory in the test phase.
If it is necessary it must be executed by
specialized persons.
Measure with a meter the distance from the
photoelectric cell (positioned at the entry of
the tunnel) to the saw disc (A).
E x a m p l e A = 1 0 0 0 m m .
This part must be inserted in the parameter
LT with the access code c 000212.
Press the key PGM till when on the display
appear LT and insert the part with the keys
▲
and .
Operate the lever at cloche C to the right to
advance the pusher and effect a complete
stroke in vain.
Position the log into the cradle and measure its
length with a meter.
Exa mpl e: l o g l en gth = 2 000 mm.
Operate the lever moving it to the right to
advance the small plate.
The log is pushed in the tunnel and noted by
the photoelectric cell. The pilot light of the
selector S light up.
N.B.: When the pilot light of the cutting selector light
up, pressing the key (B) on the display appear
the length of the log.
Example: noted length by the instrument = 2020
mm.
measured length = 2000 mm.
0 0 0
B
A
L
T 0 1
C
2
Summary of Contents for TLC 1000