![Petwalk Solutions petWALK User Manual Download Page 68](http://html1.mh-extra.com/html/petwalk-solutions/petwalk/petwalk_user-manual_1533144068.webp)
Seite 68 von 72
User Manual
Petwalk Solutions GmbH
Thermal coupling coefficient (calculated)
Standard
0.29 [W/K]
With optional frame insulation
0.18 [W/K]
Heat transition coefficient (calculated)
Standard
0.8 [W/m²K]
With optional frame insulation
0.5 [W/m²K]
Airtightness
•
n
600
= 0,0 m³/hm
•
Class 4 in accordance with test standards for windows, doors EN 12207 Pressure and suction
Water tightness
•
Class E1050 in accordance with test standards for windows, doors EN 12208 - 1999–11
Resistance to wind pressure
•
C3 in accordance with test standards for windows, doors EN12210
Climate resilience
•
Climate category IV (2(d) to DIN EN 12219)
Anti-theft security mechanisms
•
Through a contactless access control system.
•
Through a built-in alarm system.
•
Through the possibility to integrate into existing alarm system.
•
Through the use of WK2 certified fittings and highly resistant materials.
RFID (Animal chip)
•
Implanted or external transponder in accordance with ISO standards 11784/11785 FDX-B
•
Range with external transponders (necklace pendant) approx. 0 cm / 0 in to max. 20 cm / 8 in
•
Range with implant transponders (animal ID) 0 cm / 0 in to max. 5 cm / 2 in