11.9.5
RCP Panel Port Connectors
Four RCP connectors, located on the rear of the unit and illustrated in Figure 79, provide RS-485
serial communication interfaces using the PESA RCP Protocol (Document No. 81-9062-0300-0).
ALARM
SYSTEM CONTROL
ALARM
RCP PANEL PORT
4
3
2
1
NETWORK
OUTPUT MONITOR
AUX FRAME CTRL
SLOT B
3
SLOT A
REFERENCE
1
1
2
4
2
FRAME
ALARM
FRAME
CONTROL
SYSTEM
CONTROL
3
4
PRC LOOP
COM 4
COM 3 / PRC
COM 1
COM 2
FIGURE 79: RCP Panel Port Connectors
These RCPs are connected to PESA Remote Control Panels with daisy-chained cables constructed
with RCP connectors (Part No. 81-9029-0780-0) and shielded, twisted-pair cable (Part No. 81-9028-
0043-2, Belden 8451, or equivalent) as illustrated in Figure 80. The connector body has an integral
strain relief, which requires the use of a nylon cable tie, which is included with the connector. If this
cable tie is not available, use PESA Part No. 81-9021-0028-8.
81-9029-0811-0 to
Panel Port Connector
81-9029-0780-0 to
Remote Control Panel
High (+)
Low (-)
Shield(S)
1
3
2
High (+)
Low (-)
Shield(S)
1
2
3
1
2
3
1
2
3
Cable is not pin for pin! Pins 2 and 3 are swapped.
FIGURE 80: RS-485 Cable Construction
RCP PANEL PORT
4
3
2
1