10.2.4
Error Codes
In case of a fault, the sensor transmits the error codes detailed in the following table. The error
code consists of 2 bytes. The higher value byte, here 0x80, represents the IO-Link device as
the emitter. The lower value byte represents the actual fault
10.2.5
Event Data
The sensor is capable of transmitting events that occur:
Error
Error code
Comment
Device application error
0x8000
Device application error, the required service
is not operated by the sensor.
Index unavailable
0x8011
R/W access to unavailable parameter index
Unavailable subindex
0x8012
R/W access to unavailable parameter
subindex
Service temporarily
unavailable
0x8020
Write/read access to parameter limited by the
device status is not possible.
Service temporarily
unavailable
—
device
control panel
0x8022
Write/read access to parameter limited by
window control access to the sensor is not
possible.
Access denied
0x8023
Write attempt to read-only address
Invalid value range,
parameter
0x8030
For all R/W parameters outside of the valid
value range
Parameter value too large
0x8031
For all R/W parameters above the valid value
range
Parameter value too small
0x8032
For all R/W parameters beneath the valid
value range
Parameter length is too
large
0x8033
Too much data has been transmitted for the
parameter (more bytes)
Parameter length is too
small
0x8034
Too little data has been transmitted for the
parameter (too few bytes)
Application not ready
0x8082
Device application error, the required service
is not operated by the sensor
Event
Instance Type
Mode
Event
qualifier
Event
code
Description
Signal faults
APP
Warning
Appear/
Disappear
0xE4/0x
A4
0x8D40
Damping element is
too far from the
sensor.
No measured
value
APP
Warning
Appear/
Disappear
0xE4/0x
A4
0x8D41
No damping element
or no position
detection possible.