Ident-I • IRI-KHD2-4HB5 / IRI-KHA6-4HB5
Technical Data
Subject to reasonable modifications due to technical advances.
Copyright Fuchs, Printed in Germany
Fuchs Group • Tel.: Germany (06 21) 7 76-0 • USA (330) 4 25 35 55 • Singapore 7 79 90 91 • Internet http://www.pepperl-fuchs.com
D
a
te
of
is
su
e
2
7.
08
.2
0
0
1
34
9.3
Mechanical data
9.4
Indicating/operating means
9.5
Software
Ambient conditions
Operating temperature
-25 °C ... +70 °C (248 Kelvin ... 343 Kelvin
Storage temperature
-25 °C ... +85 °C (248 Kelvin ... 358 Kelvin)
Humidity
max. 75 %
rel. humidity
Mechanical specifications
Protection degree
IP20 acc. EN 60529
Connection possibilities
self-opening apparatus terminals,
max. cross sectional area 2 x 2.5 mm
2
9-pin Sub-D built-in connector
Housing material
Makrolon 6485
Construction type
K-System, 80 mm (4 TE)
Mounting
snaps onto 35 mm standard rail according to
DIN EN 50022 or screw-mountable with 2 screws
through pull-out brackets in 90 mm spacing
LED green
Read/write head active
(4 LEDs, 1 per head)
LED yellow
Code carrier detected
(4 LEDs, 1 per head)
LED red
Functional reserved
(4 LEDs, 1 per head)
LED red/green
permanently green
red-green blinking
device status
device ready for operation/communication active
v
device error
:
1 x 0.3 s green, 5 s red - communication error
3 x 0.3 s red/green blinking, 5 s red - ROM-error
4 x 0.3 s red/green blinking, 5 s red - RAM-error
Rotary switch
ring closure
0 = ring closure activ
1 = ring closure not activ
Software
The unit description for the commissioning soft-
ware is included in the scope of delivery.
IN
IN
OUT
OUT
Run/Error
Run/Error