![Pepperl+Fuchs IRI-KHA6-4HB5 Manual Download Page 35](http://html.mh-extra.com/html/pepperl-fuchs/iri-kha6-4hb5/iri-kha6-4hb5_manual_1527939035.webp)
Ident-I • IRI-KHD2-4HB5 / IRI-KHA6-4HB5
Technical Data
Subject to reasonable modifications due to technical advances.
Copyright Fuchs, Printed in Germany
Fuchs Group • Tel.: Germany (06 21) 7 76-0 • USA (330) 4 25 35 55 • Singapore 7 79 90 91 • Internet http://www.pepperl-fuchs.com
D
a
te
of
is
su
e
2
7.
08
.2
0
0
1
33
9
Technical Data
9.1
General specifications
The control interface unit is operated as an INTERBUS remote bus subscriber. The
control interface unit uses 16 bytes in the INTERBUS frame protocol. When commu-
nicating from the master to the control interface unit, 8 bytes are used for the com-
mand data. 16 bytes are available for the transmission of the read head data from the
control interface unit to the master. Here, only the cyclically transmitted process-data
channel is used; the parameter channel is not used.
Up to 4 read heads can be connected to the control interface unit. After connecting to
the system supply voltage, all connected read heads are registered and cyclically
read.
Each read head has a corresponding 4 byte data field which contains the read code
in 28 bit format. In addition, each data field contains a 3 bit read number which is in-
cremented with every new code read. The read number makes it possible to manage,
in the higher-order control system, the codes which have been read. In this way it is
possible, for example, to determine whether a new code is pending or if the same
code has been read multiple times. An additional status bit indicates whether or not a
code carrier is currently in the acquisition range.
Futures
• INTERBUS-remote bus subscriber
• 4 read heads can be connected
• transmission of all read fix codes in one cycle
• 3 LEDs per read head for function indicatio
• LED for power on / bus communicationn
• RS 485 interface
•
ID-code: 03
9.2
Electrical data
Order code
IRI-KHD2-4HB5
IRI-KHA6-4HB5
Power supply
Supply voltage
18 V DC ... 32 V DC
85 V AC ... 253 V AC,
50 Hz ... 60 Hz
Ripple
£
10 %
Current
200 mA
50 mA
Quiescent current
£
110 mA / 24 V DC
(typ)
with activ heads
190 mA
45 mA
Power consumption
5 W
10 VA