Installation
201
2-
11
17
The metal enclosure of the IDENTControl Compact and the metal enclosure of the
R/W heads complete the consistent shielding concept.
You must establish a low resistance and low inductance connection between the
shields and ground so that the shielding is not interrupted through the metal
enclosure. The complete electronics system and all routed cables are therefore
located within a Faraday cage.
5.3
Device connection
Electrical connection using plug connectors makes installation simple.
5.3.1
Power supply
Connect the power supply using an M12 connector. A plug with the following pin
assignment is located on the housing:
Compatible connecting cable see chapter 4.2.2
5.3.2
R/W head and trigger sensors
You can connect a maximum of two R/W heads (125 kHz or 13.56 MHz) or R/W
heads with electromagnetic coupling (UHF with 868 MHz) to the IDENTControl
Compact.
You can connect a trigger sensor to sockets 1 and 2 instead of a R/W head. You
can assign the trigger sensor to a R/W head. The trigger sensor must be PNP.
Compatible R/W heads see chapter 4.1.1 and compatible connecting cables see
chapter 4.2.1.
1
+ 24 V
2
NC
3
GND
4
NC
4
1
3
2
trigger switch
trigger sensor
read/write head
signal
socket at housing
2
1
3
4
5
+
A
-
+
-
B
1
2
3
4
5