Commissioning
201
2-
11
21
6
Commissioning
6.1
Connection
When the supply voltage is connected and the device is initialized, the PWR/ERR
LED lights up green. If the LED lights up red, either the initialization process has
not yet finished or there is a device fault.
6.2
Device settings
You must set the various parameters prior to commissioning.
6.2.1
Address setting
EtherCAT slaves receive their address via the controller. No manual address
assignment is necessary.
6.2.2
Non-volatile parameters
There are volatile and non-volatile parameters. Volatile parameters are reset to
their default setting when the system is switched off and on again.
Non-volatile parameters
Configure the non-volatile parameters of the R/W system with the system
commands described (see chapter 7.2.4). The "multiplex mode" and "tag type"
parameters can also be set via initial settings. "99" is preset as the tag type.
Warning!
Incorrect electrical connection
Incorrect connections may damage the system.
Caution!
Device not configured or configured incorrectly
System failure caused by incorrectly configured device
Configure the device prior to commissioning.
Parameter
Default setting
Value range
General
Multiplex mode
Off
On/off
Read/write head
Trigger mode
Off
On/off
Tag type
99
00 ... FF