![Pepperl+Fuchs IC-KP2-2HB21-2V1D Manual Download Page 80](http://html.mh-extra.com/html/pepperl-fuchs/ic-kp2-2hb21-2v1d/ic-kp2-2hb21-2v1d_manual_1527933080.webp)
201
2-
11
80
Commands
Response 1:
Response 2:
2. Example: Writing two double words from address 7 with R/W head on
channel 1
1. Position an IPC03 read/write tag in front of the R/W head on channel 1.
2. Send the command
single write words
as described in the
Command
table.
Command:
There is a read/write tag in the detection range.
0 0 04 1 000 # <CR>
0
Status
0
Reserved
04
Command code
1
Channel 1
000
Response length in bytes
#
End character
<CR>
End character
0 0 04 2 000 # <CR>
0
Status
0
Reserved
04
Command code
2
Channel 2
000
Response length in bytes
#
End character
<CR>
End character
SW
1 0007 02 ABCDEFGH # <CR>
SW
Single write words
command
1
Channel 1
0007
Address (in hexadecimal format)
02
Number of double words (4-byte words)
ABCDEFGH
Data
#
End character
<CR>
End character