3.4 ELECTRICAL CONNECTION
Colour sequence:
•
red U
•
brown V
•
white W
to observe the correct direction of rotation
Alimentazione
L(L1), N(L2), P.E.
The use of pre-insulated 6.3 x 0.8 mm. female
fastons is recommended.
Power cable stripping is recommended (without
additional ferrite):
Uscita motore
U, V, W, P.E.
The use of pre-insulated 6.3 x 0.8 mm. female
fastons is recommended.
The connection directly to the motor is already
factory set.
Analogue inputs (sensors)
• AN1: 4-20 mA, sensor 1
• AN2: 4-20 mA, sensor 2
•
AN3: 0-10 V, external set
•
AN4: 0-10 V, frequency adjustment trimmer or external set 2
• +10
• +15
The use of pre-insulated test leads is recommended.
37
P
rogramming
Translation of the original language
English
Summary of Contents for AQUADOMUS