the red STANDBY Led is OFF, holding down together the START / STOP and DOWN buttons and
powering up. The buttons can then be released after 5 seconds.
The BTLE connection can be reactivated by switching off the power, waiting at least 30 seconds until
the red STAND-BY Led turns OFF, holding down the START / STOP and UP buttons together and
powering up. The buttons can then be released after 5 seconds.
Through the application, the following are possible:
• Monitoring multiple operating parameters simultaneously.
• Obtaining power consumption statistics and checking alarm timing history.
• Running reports with the ability to enter notes, images and send e-mails or keep them in the
digital records.
•
Scheduling, filing, copying to other devices, and sharing them among multiple users.
•
Remotely controlling a device, through wi-fi or GSM, a device, or using a nearby smartphone
as a modem.
• Accessing the manuals and additional technical documentation.
• Receiving on-line help on parameters and alarms.
Monitoring
The following parameters can be monitored via the App when the “Monitor” function is selected.
Measured value [bar]
Value read by the sensor.
Set value [bar]
Value that it is intended to be kept constant.
Frequency [Hz]
Motor supply frequency.
Bus Voltage [VDC]
Bus Voltage.
Motor current [A]
Phase current absorbed by the motor.
Cosphi motor
Motor power factor (cosphi).
Power [W]
Electrical power absorbed by the motor.
Module temperature
[°C]
IGBT module temperature.
Input current [A]
Current absorbed by the network
Inverter hours [h]
Total operating hours of the inverter.
Motor hours [h]
Total motor hours.
Address
Address of the unit in COMBO operation.
ALARM HISTORY
List of the last 8 alarms.
Programming
The parameters are organized in 4 menus: IN/OUT, CONTROL, MOTOR, CONNECTIVITY.
The parameters are password protected with 2 access levels:
Installer level (IN/OUT, CONTROL)
Password: 001
Advanced Level (MOTOR, CONNECTIVITY)
Password: 002
40
P
rogramming
Summary of Contents for AQUADOMUS