8.5.5. Cleaning injector and injector screen
No.
Operation
A
Remove the softener cover, see 8.5.2. Covers removal (softener and valve), page 63.
B
Using a Torx key, unscrew and extract the injector cap (
3
).
CAUTION
Take care not to damage the injector (
2
).
C
Using pliers, gently extract the injector (
2
) from valve body.
D
Unclip the injector screen (
1
) from the injector (
2
).
E
Clean the injector (
2
) using compressed air, a soft brush or possibly a pin.
F
Clean the injector screen (
1
) with a soft brush.
NOTE
Use of descaling agent such as white vinegar might be required in case of impurities or
scale on the injector screen (
1
) and on the injector (
2
).
G
Check for o-rings integrity.
H
Assemble the injector screen (
1
) on the injector (
2
).
I
Rinse thoroughly any cleaning agent you may have used.
J
Reverse above procedure steps to rebuild.