Installer Manual Riversoft - Maintenance
Ref. MKT-IM-045 / A - 13.03.2020
71 / 90
8.5.7.3 Motor and camshaft replacement
No.
Operation
A
Remove the softener and valve covers, see 8.5.2. Covers removal (softener and valve),
page 63.
B
Disconnect the motor (
2
) from the optical sensor (
1
).
C
Loosen the two screws (
4
) and remove the clamp (
3
).
D
Remove and disassemble the camshaft (
5
) from the motor (
2
).
E
Change motor (
2
) and/or camshaft (
5
).
F
Reverse above procedure steps to rebuild.