4.5.6.3 Bypass assembly
NOTE
The following procedure is only valid for softener with bypass configuration.
The bypass assembly connects to the water system by means of a connector assembly. The connector
is secured to the plumbing and then inserted into the bypass. Clips are used to hold it in place.
Before inserting the connector:
•
check that all O-rings are in place and not damaged;
•
O-rings are pre-lubricated. Sliding surfaces should be lubricated with 100% silicone grease.
A
Firmly insert connector (
3
) into bypass.
B
Press the locking clip (
1
) into position. Make certain the clip is fully engaged.
CAUTION
Before turning on the water to the valve, rotate the two handles (
4
) on the bypass valve 2 or
3 times. This will help to place the O-rings and prevent leaking.
To remove a clip:
A
Turn off water and release water pressure at the valve.
B
Push the water line connectors (
3
) into the bypass and valve. This will help release O-rings that
may have seated in place.
C
Remove the clips (
1
) by inserting a flat screwdriver (
2
) under the top centre of the clip and lifting
(prying up).
CAUTION
Do not use pliers to remove a clip. It is likely the clip will break.
Summary of Contents for Riversoft
Page 1: ...Riversoft Water Softener INSTALLER MANUAL WATER PURIFICATION...
Page 61: ...Installer Manual Riversoft Maintenance Ref MKT IM 045 A 13 03 2020 61 90...
Page 65: ...Installer Manual Riversoft Maintenance Ref MKT IM 045 A 13 03 2020 65 90...
Page 75: ...Installer Manual Riversoft Maintenance Ref MKT IM 045 A 13 03 2020 75 90...
Page 90: ...www pentairaquaeurope com...