Installer Manual Riversoft - Installation
38 / 90
Ref. MKT-IM-045 / A - 13.03.2020
4.6.
Drain line flow controller
The DLFC requires assembly before use.
NOTE
The plumbing connectors should not be installed. See 4.5.6.2 Bypassing, page 35.
A
Using a PTFE (plumber’s tape), wrap it over threads of the flow controller (
2
).
B
Screw the flow controller (
2
) and the 90° elbow (
1
) together (hand tighten).
C
Place the ball (
5
) into the flow controller (
2
) and insert the assembly into the drain line
opening (
4
).
D
Push the assembly in and secure with the drain line clip (
3
).