Installer Manual Riversoft - Maintenance
Ref. MKT-IM-045 / A - 13.03.2020
59 / 90
* Electronic parts - durability strongly affected by power source quality and stability.
** Elastomer durability is strongly affected by raw water concentration in chlorine and its derivative.
*** 368 being not equipped with an Aircheck, therefore the safety brine valve should be equipped with and aircheck.
**** Wear part.
8.2.1. Maintenance instructions
•
Disinfect and clean the system at least once a year or if the treated water has an off-taste or an
unusual odour;
Optical sensor
Check
Check
Check
Check
Replace
Inlet hardness
Check
Check
Check
Check
Check
Residual
hardness
Check/adapt
mixing screw if
necessary
Check/adapt
mixing screw if
necessary
Check/adapt
mixing screw if
necessary
Check/adapt
mixing screw if
necessary
Check/adapt
mixing screw if
necessary
Electronic/
settings*
Check
Check
Check
Check
Check/ replace
if necessary
Transformer*
Check
Check
Check
Check
Check/ replace
if necessary
Turbine
manifold****
Check and
Clean
Check and
Clean
Check and
Clean
Check and
Clean
Replace
Turbine cable
Check
Check
Check
Check
Replace
Valve
watertightness
Check
Check
Check
Check
Check
Valve to piping
watertightness
Check
Check
Check
Check
Check
Brine tank &
brine well
Clean
Clean
Clean
Clean
Clean
Safety brine
valve (if
present)
Check and
Clean
Check and
Clean
Check and
Clean
Check and
Clean
Check and
Clean
Brine tube
Clean
Clean
Clean
Clean
Clean
Brine line
Clean
Clean
Clean
Clean
Clean
Cabinet body
and cover
(external)
Clean
Clean
Clean
Clean
Clean
Items
1 year
2 year
3 year
4 year
5 year
Summary of Contents for Riversoft
Page 1: ...Riversoft Water Softener INSTALLER MANUAL WATER PURIFICATION...
Page 61: ...Installer Manual Riversoft Maintenance Ref MKT IM 045 A 13 03 2020 61 90...
Page 65: ...Installer Manual Riversoft Maintenance Ref MKT IM 045 A 13 03 2020 65 90...
Page 75: ...Installer Manual Riversoft Maintenance Ref MKT IM 045 A 13 03 2020 75 90...
Page 90: ...www pentairaquaeurope com...