background image

System tested and certified by NSF

International against NSF/ANSI Standard 44

for hardness reduction, efficiency and the

reduction of barium and radium 226/228,

and certified to NSF/ANSI Standard 372.

Système évalué et certifié par NSF Inter-

national selon la norme NSF/ANSI 44 pour la

réduction de la dureté de l’eau, l’efficacité et

la réduction de baryum et radium 226/228,

et certifié selon la norme NSF/ANSI 372.

P/N 7339939 (Rev. E  5/13/14)

Use & Care Guide

Guide de l’utilisation et d’entretien

English / Français

Model / Modèle  625.75116

Kenmore

®

Water Softener

with High Flow Valve

Adoucisseur d’eau

avec soupape à haut débit

®

System tested and certified by the Water

Quality Association against CSA B483.1.

Système évalué et certifié par Water Quality

Association selon la norme CSA B483.1.

C

USA

Sears Canada Inc.

290 Yonge Street

Toronto, Ontario  M5B 2C3  Canada

www.kenmorewater.com

www.kenmore.com

www.sears.ca

Summary of Contents for 625.75116

Page 1: ...yum et radium 226 228 et certifié selon la norme NSF ANSI 372 P N 7339939 Rev E 5 13 14 Use Care Guide Guide de l utilisation et d entretien English Français Model Modèle 625 75116 Kenmore Water Softener with High Flow Valve Adoucisseur d eau avec soupape à haut débit System tested and certified by the Water Quality Association against CSA B483 1 Système évalué et certifié par Water Quality Associ...

Page 2: ... product 3 Damage to or failure of this product if it is not installed operated or maintained according to the all instructions supplied with the product 4 Damage to or failure of this product resulting from accident abuse misuse or use for other than its intend ed purpose 5 Damage to or failure of this product caused by the use of detergents cleaners chemicals or utensils other than those recomme...

Page 3: ...al p Use only lead free solder and flux for all sweat sol der connections as required by federal codes when installing soldered copper plumbing p Use care when handling the water softener Do not turn upside down or drop p Avoid installing in direct sunlight Excessive heat may cause distortion or other damage to non metallic parts p This water softener works on water pressures of 20 psi minimum to ...

Page 4: ...el is efficiency rated The efficiency rating is valid only at the minimum salt dose This softener has a demand initiated regeneration D I R feature that complies with specific performance specifications intended to mini mize the amount of regenerant brine and water used in their operation This softener has a rated softener efficiency of not less than 3 350 grains of total hardness exchange per pou...

Page 5: ...IN OUT 19 3 4 40 1 4 FRONT VIEW SIDE VIEW 5 Questions Call the Kenmore Water Line 1 800 426 9345 or visit www kenmorewater com Dimensions IN OUT 105 4 cm 116 8 cm 102 2 cm 50 2 cm 41 9 cm 8 6 cm OUT IN FRONT VIEW SIDE VIEW Figure 1 ...

Page 6: ...TO INSTALL WATER TREATMENT EQUIPMENT Shows sequence of equipment only not all items are needed in all applications Central Water Filtration System Sediment Cartridge Filter Water Heater Water Softener Untreated Water to Outside Faucets Hot Water to House Cold Water to House Iron Filter Pressure Tank City Water Supply Well Water Supply Well Pump OR Figure 3 Always locate an Iron Filter UPSTREAM of ...

Page 7: ...ater Water Softener Outside Faucet hard water Outside Faucet hard water Soft cold water Soft hot water Figure 4 WHERE TO INSTALL THE WATER SOFTENER Review the following points before you choose a place to put your softener 1 Place as close as possible to but always downstream from the pressure tank well water or water meter city water 2 Place as close as possible to a water drain such as a floor d...

Page 8: ... plumbing skip step 6 but perform step 7 Complete the following steps to assemble the adaptors and or the included single bypass valve 1 Close the shutoff valve on the house main water pipe near the water meter or pressure tank to turn off the water 2 Shut off the gas or electric supply to the water heater 3 Open the highest and lowest water faucets in your house This will let water drain from the...

Page 9: ...to the main water pipe Make sure that the incoming water supply pipe goes to the valve inlet side CAUTION Never solder fittings while connected to nonmetallic parts Wait until soldered pipe has cooled before connection See Fig 10 CAUTION Be careful when putting pipe fittings togeth er Do not cross thread and do not over tighten Figure 10 Incoming Hard Water Main Water Pipe 1 Cut pipe to correct le...

Page 10: ...to use if running a drain line overhead To adapt a copper drain tube to the softener purchase a compression fitting 1 4 NPT female pipe threads x 1 25 cm minimum O D tube and tubing from your local hardware store CONNECT SALT TANK OVERFLOW HOSE 1 Locate the rubber grommet adaptor elbow and tube clamp see Fig 11 that are in the parts bag 2 Push the grommet into the hole in the salt tank wall so tha...

Page 11: ...utward toward service pausing several times to allow the softener to pressurize gradually b 3 Valve Bypass Fully close the bypass valve and open the outlet valve Slowly open the inlet valve pausing several times to allow the softener to pres surize gradually 5 After about three minutes open a hot water faucet for about one minute or until all air is expelled then close 6 Close both cold water fauc...

Page 12: ... s into the plumbing system along with the water softener be sure to restore electrical con tinuity across all removed metal pipe sections INSTALL COVERS After installing your water softener put the covers on Angle the covers so the top cover clips onto the back first then bring down in front and clip on the tabs inside the rim and lower the salt lid closed See Fig 5 CONNECT TO ELECTRICAL POWER Th...

Page 13: ...rrect time is displayed press the SELECT button and the display will change to show the Hardness screen SET WATER HARDNESS NUMBER If you completed the previous step the words SET HARDNESS should show in the display Otherwise press the SELECT button several times until they do 1 Press the r UP or s DOWN buttons to set the hardness of your water supply in grains per gallon The default is 25 NOTE If ...

Page 14: ...onitor indicator light to remind you to add salt to the storage tank NOTE You must set salt level each time salt is added to the water softener NOTE The salt monitor system estimates salt levels and accuracy will vary with different salts To set this monitor system If you completed the previous step the words SET SALT LEVEL should show in the display Otherwise press the SELECT button several times...

Page 15: ...r from working To maintain optimum performance of your water softener the salt tank should be cleaned out every 2 to 3 years POTASSIUM CHLORIDE KCl SALT If you choose Potassium Chloride KCl as a regenerant following these suggestions will help give you years of maintenance free service 1 Place only one bag of KCl in your softener at a time the salt storage tank should contain no more than 27 kg of...

Page 16: ...r as set If you decide to cancel the regeneration before it starts press and release the REGENERATION button once more RECHARGE TONIGHT will stop flashing in the display Figure 25 Figure 23 4 Press the r UP or s DOWN buttons to set the salt level to match the number on the brinewell At level 2 or below the Low Salt indicator will flash If you want to turn the salt monitor off press the s DOWN butt...

Page 17: ...his feature is ON SALT EFFICIENCY When this feature is ON the water softener will oper ate at salt efficiencies of 4000 grains of hardness per pound of salt or higher The softener may recharge more often using smaller salt dosage and less water This softener is shipped with the efficiency feature set OFF To turn this feature ON 1 Press and hold the SELECT button until the display shows 000 BACKWAS...

Page 18: ... Bridge Salt Empty Space Water Level 3 5 cm Pencil Mark Broom Handle Push tool into salt bridge to break Service Information ALWAYS MAKE THESE INITIAL CHECKS FIRST 1 Does the time display show the correct time of day If display is blank check power source to the sof tener If time is flashing power was off for a long peri od The softener resumes normal operation but regenerations occur at the wrong...

Page 19: ...lt lid Valve drain hose is plugged or restricted Hose must not have any kinks sharp bends or any water flow blockage See Valve Drain Requirements Intermittent hard water Incorrect time set Check and change time setting Incorrect water hardness set Refer to Set Water Hardness Number to set correctly Hot water being used when softener is regenerating Avoid using hot water while the softener is regen...

Page 20: ...otating from one position to another the position switch indicator will show the letter P switch closed There is likely a problem if indications vary from this pattern OTHER INFORMATION While in the diagnostics screen the following information is available and may be beneficial for various reasons This information is retained by the electronic controller from the first time electrical power is app...

Page 21: ...egin Verify brine draw from the brine tank by shining a flashlight into the brinewell and observing a noticeable drop in the liq uid level 5 If the softener does not draw brine nozzle and or venturi dirty nozzle and venturi not seated properly on gasket restricted drain check drain fitting and hose ineffective nozzle and venturi seal other inner valve problem rotor seal rotor disc wave washer etc ...

Page 22: ...800 426 9345 or visit www kenmorewater com 8 7 6 5 Water Softener Exploded View Valve Assembly See Pages 24 25 for parts Kenmore Model No 625 75116 2 3 4 5 6 Rating Decal Location 20 19 21 18 17 25 22 23 7 8 10 11 9 14 12 13 15 16 26 24 27 28 1 ...

Page 23: ...14 12 á Adaptor Elbow 13 á Grommet 14 á Hose Clamp 15 7327584 Repl Bottom Distributor Key No Part No Description 16 0502272 Resin 17 7327607 Repl Resin Tank 17 8 x 101 6 cm 7112963 Distributor O Ring Kit includes Key Nos 18 20 18 á O Ring 69 9 x 76 2 cm 19 á O Ring 20 6 x 27 0 cm 20 á O Ring 73 0 x 82 6 cm 21 7077870 Top Distributor 7331177 Tank Neck Clamp Kit includes 2 ea of Key Nos 22 23 22 á C...

Page 24: ...ine 1 800 426 9345 or visit www kenmorewater com Valve Assembly Exploded View Cross Section View 91 50 51 52 53 54 55 56 57 58 59 60 66 61 67 62 63 70 64 68 69 65 71 72 73 74 75 76 77 79 78 Seal Wear Strip 80 81 82 83 84 85 86 87 88 89 90 ...

Page 25: ... 4 Not illustrated Ù Not included with water softener 92 Valve Parts List Key No Part No Description 7113040 Turbine Support Assembly including 2 O Rings See Key No 72 1 ea of Key Nos 73 74 73 á Turbine Support Shaft 74 á Turbine 75 7082053 Valve Body 76 7081201 Retainer Nozzle Venturi 77 7342649 O Ring 6 4 x 9 5 mm pack of 2 78 1202600 Nut Ferrule 7238450 Nozzle Venturi Assembly includes Key Nos ...

Page 26: ...Parts Repair Service Center 1 800 488 1222 U S A 1 800 469 4663 Canada www sears com www sears ca To purchase a protection agreement on a product serviced by Sears 1 800 827 6655 U S A 1 800 361 6665 Canada Registered Trademark TM Trademark of KCD IP LLC in the United States or Sears Brands LLC in other countries Marca Registrada TM Marca de Fábrica de KCD IP LLC en Estados Unidos o Sears Brands L...

Reviews: