![Pentair PVM3 Original Instruction Manual Download Page 7](http://html1.mh-extra.com/html/pentair/pvm3/pvm3_original-instruction-manual_1524592007.webp)
5
EN
ORIGINAL INSTRUCTION
T [°C]
20
30
40
50
60
70
80
90
100
110
120
K
T
[m]
0,2
0,4
0,8
1,3
2,2
3,3
5,0
7,4
11
15
22
H [m]
0
500
1000
1500
2000
2500
3000
K
H
[m]
0
0,55
1,10
1,65
2,20
2,75
3,30
To prevent overheating of the internal pump components, the pump should not be used at flows below the minimum flow rate.
The curve below shows the minimum flow rate required as a percentage of the pump nominal flow rate in relation to the liquid tempe
-
rature
Do not run the pump against a closed discharge valve for longer than a few seconds.
See the motor nameplate.
Make sure that the supply voltages, phase and frequencies correspond to the motor specifications.
4.7 ELECTRIC DATA
Motors up to and including 4 kW: Maximum 100 starts per hour. Motors of 5.5 kW and up: Maximum 40 starts per hour..
If you use another brand of motor then check the manufacturer’s instructions for the maximum frequency of starts.
4.8 NUMBER OF STARTS PER HOUR
4.6 MINIMUM NOMINAL FLOW RATE
Danger to equipment and operation.
ATTENTION
Danger to equipment and operation.
ATTENTION
Danger to equipment and operation.
ATTENTION
Summary of Contents for PVM3
Page 101: ...99 1 99 2 101 3 102 4 102 5 104 6 105 7 108 8 109 9 110 10 111 140 1 1 1 1 2 1 3...
Page 102: ...100 1 4 1 5 1 6 1 7 8 FI RCD 30...
Page 106: ...104 5 5 2 5 1...
Page 107: ...105 6 6 1...
Page 110: ...108 6 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 7...
Page 111: ...109 8 8 1...
Page 112: ...110 8 2 PVM PVMI PVMX 1 3 5 6 6 Bushing Bypass valve 9...
Page 113: ...111 10...
Page 114: ...112...
Page 115: ...113 1 113 2 115 3 116 4 116 5 118 6 119 7 122 8 123 9 124 10 125 140 1 1 1 2 1 3 1 AR...
Page 116: ...114 4 1 5 1 6 1 7 1 8 FI RCD 30 AR...
Page 120: ...118 5 2 5 1 5 AR...
Page 121: ...119 6 1 6 AR...
Page 124: ...122 4 6 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 7 3 AR...
Page 125: ...123 8 1 8 AR...
Page 126: ...124 2 8 5 3 PVM PVMI PVMX 1 6 6 Bushing Bypass valve 9 AR...
Page 127: ...125 10 AR...
Page 128: ...126 AR...
Page 138: ...136...
Page 147: ...145 AR...