background image

INSTALLATION

INSTALLATION

Table 2 - Circuit breaker and wire sizes

Motor

Drive 

Model

Volts Motor HP

Wire Size*

Circuit 

Breaker**

Generator 

(kVA)***

Input

Output

2-wire

PID2000-

1123

230

1-1/2

2.5mm² 2.5mm²

25 (with RCD, 

Ref page2)

5.3

3-wire

PID2000-

1123

1-1/2

2.5mm² 2.5mm²

25 (with RCD, 

Ref page2)

5.3

2

5.8

 
* Wiring size will change depending on the length of wire. See Table 3
** With properly-sized circuit breakers, the Drive is protected from short circuit on the input and 
the output. There is no risk of fire or electrical shock due to a short circuit. The Drive has NEC 
Class 10 overload protection.
*** Minimum 240V generator size.

NOTICE

 Information in Table 3 applies ONLY to PENTEK® motors. For other motors, refer to motor 

manufacturer specifications for wire sizing.

Table 3 - Wire Sizing, Drive to Pentek 3-Wire, 1-Phase Motor, 40°C Ambient, and 5 percent 
Voltage Drop, 60C and 75C Insulation (copper only).

Motor P/N

Motor Rating

Maximum Cable Length in M

PENTAIR

Volts

HP

Rate 

Current

1.5 

mm²

2.5 

mm²

4.0 

mm²

6  

mm²

10 

mm²

16 

mm²

XMEC981M

230

0.75

5

57

95

152

-

-

-

XMEC982M

1

6.2

45

75

120

174

-

-

XMEC983M

1.5

8.1

33

53

85

127

210

-

XMEC943M

2

10.4

23

38

63

92

154

246

XMEC945M

3

15

-

28

45

67

112

180

XMEC984M

5.5

28.1

-

-

-

33

55

88

Mounting the Drive

To mount the Drive as shown in Figure 6, follow this 
procedure:
1.     First, remove the cover by backing out screw at 

bottom of front cover.

2.    Push on backplate with thumbs while pulling the 

cover toward you with index fingers, creating a 
gap. See Figures 3 and 4.

3.     Pull bottom of cover towards you; lift up on 

cover and remove. See Figure 5.

Gap

Figure 3 - Separate cover and backplate

Figure 4 - Gap between cover and backplate

Figure 5 - Pull out bottom of cover

4.    With the cover removed, permanently 
mount the Drive using the top slotted hole, 
plus either the three bottom holes (for flat 
surface mounting) or the center bottom hole 
(for attaching to a post or stud). See Figure 6. 

5.     Ensure the Drive’s ventilation holes 
are not blocked and there is enough space 
around it to allow free air flow (minimum 
75mm clearance on top, bottom, and sides). 
See Figure 6. Once the Drive is mounted, 
electrical wiring can be connected.

 
 
 
 
 
 
 
 
 

 
 

6.     To reattach the Drive cover, hook the 
top of it on backplate (be sure to leave a gap). 
Lower bottom of cover into place. Push cover 
evenly against backplate, eliminating the gap. 
See Figure 7.

7.     Replace screw at bottom of front cover.

Figure 6 - Attaching Drive to wall

5997 0412

Typical 

230VAC 

Circuit 

Breaker 

(Double Width)

Figure 7 - Re-attaching Drive cover

PENTEK IntelliDrive

 Owner’s Manual

PENTEK IntelliDrive

 Owner’s Manual

7

6

Summary of Contents for PENTEK INTELLIDRIVE PID2000-1123

Page 1: ...SSURE CONTROLLER Should the installer or owner be unfamiliar with the correct installation and or operation of this type of equipment please contact the distributor or manufacturer for the correct advice before proceeding with the installation or operation of this product ...

Page 2: ...age 6 for circuit breaker sizing with no other appliances on the circuit Risk of burns The drive can become hot during normal operation Allow it to cool for 10 minutes after shut down before handling it to avoid burns Risk of electric shock A means for disconnection from the supply mains having a contact separation in all poles must be incorporated in the fixed wiring in accordance with the wiring...

Page 3: ...gnal The Drive senses and processes the signal in the PID Proportional Integration Derivative control When operating in AUTOSTART mode the Drive increases and decreases the speed of the pump motor as needed to maintain constant pressure in the piping system Keypad The keypad programs the Drive monitors the status of the pump and displays faults if they occur Each button has a unique function as de...

Page 4: ...984M 5 5 28 1 33 55 88 Mounting the Drive To mount the Drive as shown in Figure 6 follow this procedure 1 First remove the cover by backing out screw at bottom of front cover 2 Push on backplate with thumbs while pulling the cover toward you with index fingers creating a gap See Figures 3 and 4 3 Pull bottom of cover towards you lift up on cover and remove See Figure 5 Gap Figure 3 Separate cover ...

Page 5: ...ly accepts 230V single phase input power If incoming power does not match this have a qualified electrician alter supply voltage to 230V 1Ph before connecting it to the Drive Terminal Removable pull down 01 01 I1 I1 I2 I2 V V AI AI P N SD CARD Transducer Cable Connections Submersible Motor 3 Ph 3 W 1 Ph follow colors as above Submersible Motor 1 Ph 2 W connect to Y and B any order Above Ground Mot...

Page 6: ... installed before operating the PENTEK INTELLIDRIVE Most installations will only require the initial startup settings However the installer may need to set additional parameters Information about accessing all parameters explanations of their functions and procedures for changing parameter values will be found later in this section 1 Program the Drive Apply power to the PENTEK INTELLIDRIVE Setup G...

Page 7: ...9 lists all available commands and parameters for the PENTEK INTELLIDRIVE 6569 0512 Press PSI Preset Use arrows to change the value Press Enter to Save Press Enter Figure 14 Change PSI Setpoint using PSI Preset 6568 0512 Press Auto Start Use arrows to change the value Press Enter to Save Press Enter Verify Running Fixed Press displayed on screen Figure 13 Change PSI Setpoint while running pump Key...

Page 8: ...VALUE DESCRIPTION DEFAULT MIN MAX Ex Runtime Excessive Runtime Detection _ Enabled Disabled Enabled Enables or disables Excessive Runtime Detection Excessive Runtime Hours Hours 24 1 100 Number of hours Drive can run before it faults on Excessive Runtime Dry Run Auto Restart Delay Minutes 10 Min 3 Min 60 Min Time Drive waits to restart pump when Dry Run is detected Number of Resets 3 0 5 Number of...

Page 9: ...and 8 Amps at up to 230VAC O1 Output relay dry contacts connection Programmed to close when pump is Running or Faulted Positive wires of an external device See Figures 17 and 18 P Positive connection of an RS 485 communication device see Figure 15 Positive wire from RS 485 device Per RS 485 Standard N Negative connection of an RS 485 communication device see Figure 15 Negative wire from RS 485 dev...

Page 10: ...n Possible leak Check for pipe break or large leak Dry running pump Check water level in well Ground Fault Ground wire shorted to motor phase Check the ground wire for short to motor phase wire or check insulation integrity with a megger Long motor cable length If motor cable length is more than 305m a reactor or filter may be needed to limit capacitance between motor wires System Not Grounded Ung...

Page 11: ... Fault Internal voltages are out of range Drive will auto reset and attempt to clear fault Fault Reset can be pressed to clear fault as well Then try to operate pump If fault continues Drive may need replacement Hardware Fault Internal hardware failure Fault Reset can be pressed to clear fault Then try to operate pump If fault continues Drive may need replacement External Fault The external device...

Page 12: ...rial No Dealer Installer Installer Phone No Date of Installation Wire Lengths in Meters Circuit Breaker to Drive PENTEK INTELLIDRIVE to Motor Supply Voltage Note to Installer Record the data listed above for future reference Give manual to end user or attach to PENTEK INTELLIDRIVE when installation is complete OWNER S INFORMATION PENTEK IntelliDrive Owner s Manual 22 ...

Page 13: ...yright law Any reproduction display publication modification or distribution is strictly prohibited without the prior written permission from Pentair Disclaimer Pentair reserves the right to change product specifications and products details All product images are for reference purposes only and may not represent actual and or current product 2022 Pentair All rights reserved ...

Reviews: