background image

IMPORTANT
Please attach your sales invoice/docket here as proof of purchase should 

warranty service be required.
Please do not return Warranty Form to Pentair Australia - 

please retain for your records. 

Purchased From ...................................................................................................................
Purchase Date.....................................  Serial No..............................  Model No...................

L300260  0616

1-21 Monash Drive, 

Dandenong South, Vic 3175

Australia 

 

 National Customer Service:   Phone:   1300 137 344  

    

 

 

Fax:   

1800 006 688

 National Dealer Locator:  

Phone:   1800 664 266

 Email:            

 

[email protected] 

 Web:              

 

www.pentairpool.com.au

New Zealand  

 National Customer Service:   Phone:   0800 654 112  

  

 

 

Fax:   

0800 806 642

 National Dealer Locator:  

Phone:   0800 664 269

 Email:           

 

[email protected] 

 Web:          

 

www.pentair.co.nz

International Australia/New Zealand        

    

 

 

Phone:    +61 3 9709 5800 

    

 

 

Fax:   

+61 3 9709 5888

© Information contained here-in remains the property of Pentair Pty Ltd. Any reproduction,display, 

publication, modification or distribution is strictly prohibited without the prior written permission of 

Pentair Pty Ltd. 

Disclaimer:  

 

Every endeavour has been made to publish the correct details in this owners manual.

No responsibility will be taken for errors, omissions or changes in product specifications.
Pentair reserves the right to change product specifications and products details.

All product images are for reference purposes only and may not represent actual 
and/or current   product.

P

ANTER

A

e v o l u t i o n

Genuine Onga Spare Parts Supplied By:

Freephone 0508 634 341

7 Monier Pl, Mt Wellington, Auckland 1060, New Zealand

Summary of Contents for ONGA Eco Select PANTERA evolution

Page 1: ...u should contact the distributor manufacturer for the correct advice before proceeding with the installation or operation of this product The pump operator or owner must be provided with this owner s...

Page 2: ...residential and commercial pool owners and operators The Eco Select brand identifies our most eco friendly products As the global leader in pool and spa equipment we ve made a strong commitment to de...

Page 3: ...Dimensions Installation Pump Positioning Piping Pool Outlets Electrical Equipotential Bonding Operation Priming the Pump Speed Selection Other modes Automation control Service Maintenance Troubleshoot...

Page 4: ...h efficiency and low noise levels Fault protected motor prevents damage by automatically shutting down the motor in the event of a locked rotor or over current condition Low speed operation and effici...

Page 5: ...m PVC pressure pipe to AS NZS 1477 Max Total Head 20m Water Temperature Range 5 C 40 C Maximum Ambient temperature 55 C Recommended pH Range 7 2 7 8 Guide Only Sound Power Level Lwa Low 53dB High 69dB...

Page 6: ...tion Hydraulic Performance Dimensions 5 Head m Flow L min 0 00 2 00 4 00 6 00 8 00 10 00 12 00 14 00 16 00 18 00 20 00 0 50 100 150 200 250 300 350 400 450 Pantera Evolution Performance Chart Low 1450...

Page 7: ...h ventilation to keep ambient temperature below the motor s rated ambient temperature whenever the pump is running If installed in an enclosure pump house the enclosure must have adequate ventilation...

Page 8: ...ct voltage can cause fire or seriously damage pump and voids warranty d Voltage at pump must not be more than 6 above or 10 below motor nameplate rated voltage or pump may overheat causing overload tr...

Page 9: ...e o ring The original equipment O ring contains a permanent internal lubricant a Before removing trap lid SWITCH OFF POWER SUPPLY to pump b CLOSE SHUT OFF VALVES on suction and discharge pipes if pres...

Page 10: ...then automatically will return to low 9 Cleaning with a suction cleaner Backwashing filter Operating some water features such as jets or waterfalls Solar heating 5 sec Press hold for 5 seconds On eac...

Page 11: ...e through the gland nut and then through the gland as shown in Figure 2 6 Connect the control cable to the circuit board connectors marked High Speed and Low Speed as shown in Figure 3 7 Connect the o...

Page 12: ...is operating If leaks are noticed clean and grease the o rings or replace if necessary Check that there are no leaks from under the pump If there are this could be a sign of a leaking mechanical seal...

Page 13: ...st prime Low speed setting Clogged pipe strainer impeller filter system Pump must be primed make sure that the pump casing and strainer are full of water Refer priming instructions Make sure there are...

Page 14: ...ection of this manual Ensure motor fins are clean and fan is intact and free from blockages Ensure adequate ventilation and reduce ambient temperature Switch off the power to the pump Tighten the casi...

Page 15: ...AL PACK OF 25 801303 12 DIFFUSER 303460K 13 IMPELLER 506840K 14 SEPERATOR PLATE 408730 15 CASING ASSEMBLY INCLUDES ITEMS 16 17 18 19 801200 16 CASING PANTERA POOL SEE CASING ASSEMBLY 17 STRAINER BASKE...

Page 16: ...b www pentair co nz International Australia New Zealand Phone 61 3 9709 5800 Fax 61 3 9709 5888 Information contained here in remains the property of Pentair Pty Ltd Any reproduction display publicati...