background image

Service & Maintenance

To avoid dangerous or fatal electrical 
shock hazard, turn OFF power to 
pump and remove plug from power 
outlet before working on pump.

Do not operate pump with trap 
basket missing or damaged.

It is essential for the longevity of the pump that regular service and maintenance be carried out. The Onga Eco800 
incorporates high velocity moving parts and is pumping water containing harsh pool chemicals. Some parts which will wear 
during the normal operation and expected life of the pump.

Once per week

Once per month

FREQUENCY

CHECK

Inspect trap basket, and empty of any leaves 
and other debris. Leaves and other debris 
that collects in basket will choke off water 
flow through the pump and reduce efficiency 
and performance. See below instructions on 
cleaning the trap.

Clean area around pump and ensure there 
are no leaves or debris which could become 
a fire hazard or choke the motor fan. 

Check the pump to ensure no water is leaking 
from inlet and outlet joints, whilst pump is 
operating. If leaks are noticed, clean and grease 
the o-rings or replace if necessary.

Check that there are no leaks from under the 
pump. If there are, this could be a sign of a 
leaking mechanical seal. Call a Pentair Service 
Agent immediately, to prevent damage to the 
motor.

Check pump and motor for insects and pest 
infestations and ensure that motor fins are clean 
of dust and dirt. Clean if necessary.

Follow instructions below to clean trap:

1.  Switch off power to pump, close valves in suction and discharge, and release all pressure from system before  

proceeding. 

2.  Remove trap cover (turn counter clockwise). If necessary, tap handles gently with a rubber mallet. 
3.  Remove strainer basket and clean. Ensure all holes in basket are clear, flush basket with water and replace in trap with 

large opening at pipe connection port (between ribs provided). If basket is replaced backwards, the cover will not fit on 
trap body. 

     To clean transparent cover, use water and neutral soap only. Do not use solvents. 
4.  Clean and inspect lid o-ring; reinstall on trap. Clean O-ring groove on trap body and replace cover. To help keep cover 

from sticking, tighten hand tight only. 

5.  Prime pump (refer priming instructions). 

11

Summary of Contents for ONGA Eco Select PANTERA evolution

Page 1: ...u should contact the distributor manufacturer for the correct advice before proceeding with the installation or operation of this product The pump operator or owner must be provided with this owner s...

Page 2: ...residential and commercial pool owners and operators The Eco Select brand identifies our most eco friendly products As the global leader in pool and spa equipment we ve made a strong commitment to de...

Page 3: ...Dimensions Installation Pump Positioning Piping Pool Outlets Electrical Equipotential Bonding Operation Priming the Pump Speed Selection Other modes Automation control Service Maintenance Troubleshoot...

Page 4: ...h efficiency and low noise levels Fault protected motor prevents damage by automatically shutting down the motor in the event of a locked rotor or over current condition Low speed operation and effici...

Page 5: ...m PVC pressure pipe to AS NZS 1477 Max Total Head 20m Water Temperature Range 5 C 40 C Maximum Ambient temperature 55 C Recommended pH Range 7 2 7 8 Guide Only Sound Power Level Lwa Low 53dB High 69dB...

Page 6: ...tion Hydraulic Performance Dimensions 5 Head m Flow L min 0 00 2 00 4 00 6 00 8 00 10 00 12 00 14 00 16 00 18 00 20 00 0 50 100 150 200 250 300 350 400 450 Pantera Evolution Performance Chart Low 1450...

Page 7: ...h ventilation to keep ambient temperature below the motor s rated ambient temperature whenever the pump is running If installed in an enclosure pump house the enclosure must have adequate ventilation...

Page 8: ...ct voltage can cause fire or seriously damage pump and voids warranty d Voltage at pump must not be more than 6 above or 10 below motor nameplate rated voltage or pump may overheat causing overload tr...

Page 9: ...e o ring The original equipment O ring contains a permanent internal lubricant a Before removing trap lid SWITCH OFF POWER SUPPLY to pump b CLOSE SHUT OFF VALVES on suction and discharge pipes if pres...

Page 10: ...then automatically will return to low 9 Cleaning with a suction cleaner Backwashing filter Operating some water features such as jets or waterfalls Solar heating 5 sec Press hold for 5 seconds On eac...

Page 11: ...e through the gland nut and then through the gland as shown in Figure 2 6 Connect the control cable to the circuit board connectors marked High Speed and Low Speed as shown in Figure 3 7 Connect the o...

Page 12: ...is operating If leaks are noticed clean and grease the o rings or replace if necessary Check that there are no leaks from under the pump If there are this could be a sign of a leaking mechanical seal...

Page 13: ...st prime Low speed setting Clogged pipe strainer impeller filter system Pump must be primed make sure that the pump casing and strainer are full of water Refer priming instructions Make sure there are...

Page 14: ...ection of this manual Ensure motor fins are clean and fan is intact and free from blockages Ensure adequate ventilation and reduce ambient temperature Switch off the power to the pump Tighten the casi...

Page 15: ...AL PACK OF 25 801303 12 DIFFUSER 303460K 13 IMPELLER 506840K 14 SEPERATOR PLATE 408730 15 CASING ASSEMBLY INCLUDES ITEMS 16 17 18 19 801200 16 CASING PANTERA POOL SEE CASING ASSEMBLY 17 STRAINER BASKE...

Page 16: ...b www pentair co nz International Australia New Zealand Phone 61 3 9709 5800 Fax 61 3 9709 5888 Information contained here in remains the property of Pentair Pty Ltd Any reproduction display publicati...

Reviews: