Installation

The pump must be installed and serviced by a suitably qualified person in order to avoid 
hazard. Incorrectly installed or tested equipment may fail, causing severe injury or property 
damage.

These instructions are a guide only. Should you the installer or owner of the product be 
unfamiliar with the correct installation or operation of this product you should contact a 
suitably qualified person for advice.

Do not connect system to high pressure or mains water system.

This pump is not intended for use by persons (including children) with reduced physical, 
sensory or mental capabilities, or lack of experience and knowledge, unless they have been 
given supervision or instruction concerning use of the appliance by a person responsible for 
their safety.

Children should be supervised to ensure that they do not play with the pump. 

The Pantera Evolution  is electrically connected. Ensure that it is isolated from electrical 
supply during installation and any subsequent service work.  

For best performance, allow pump 
suction inlet height to be as far 
below water level as possible and 
allow the use of short, direct suction 
pipe with minimum bends (to reduce 
friction losses).

1. Plan the position of the pump

a)  Have enough ventilation to keep ambient temperature below the motor's rated ambient temperature whenever the pump  

is running. If installed in an enclosure/pump house, the enclosure must have adequate ventilation (200sq.cm min, inlet & 
outlet) and air circulation Allow 200mm to keep rear of motor clear.

b)  Have adequate floor drainage to prevent flooding and be protected from excess moisture.
c)  Be solid, level, rigid and vibration free. 
d)  To reduce vibration and pipe stress, bolt pump to mount. Fixing holes accept 12mm fasteners. 
e)  Be within 2m of a power outlet for electrical connection (refer to AS/NZS 3000 for rules regarding connection of   

electrical  equipment in pool zones).

f)   Allow adequate access for servicing pump and piping.

2. Piping

For best performance, allow pump 
suction inlet height to be as far 
below water level as possible and 
allow the use of short, direct suction 
pipe with minimum bends (to reduce 
friction losses).

a)  Use only Australian Standard PVC pressure pipe. For best performance use at least 50mm diameter pipe for all 

connections to the pump. Never use a suction pipe smaller than pump suction connections (50mm) and use larger pipe 
for long suction distances.

b)  To avoid stress on the pump, support both suction and discharge pipes independently. Place these supports as close to 

the pump as possible. 

c)  To avoid a strain left by a gap at the last connection, start all piping at the pump and run pipe away from the pump. 

6

Summary of Contents for ONGA Eco Select PANTERA evolution

Page 1: ...u should contact the distributor manufacturer for the correct advice before proceeding with the installation or operation of this product The pump operator or owner must be provided with this owner s...

Page 2: ...residential and commercial pool owners and operators The Eco Select brand identifies our most eco friendly products As the global leader in pool and spa equipment we ve made a strong commitment to de...

Page 3: ...Dimensions Installation Pump Positioning Piping Pool Outlets Electrical Equipotential Bonding Operation Priming the Pump Speed Selection Other modes Automation control Service Maintenance Troubleshoot...

Page 4: ...h efficiency and low noise levels Fault protected motor prevents damage by automatically shutting down the motor in the event of a locked rotor or over current condition Low speed operation and effici...

Page 5: ...m PVC pressure pipe to AS NZS 1477 Max Total Head 20m Water Temperature Range 5 C 40 C Maximum Ambient temperature 55 C Recommended pH Range 7 2 7 8 Guide Only Sound Power Level Lwa Low 53dB High 69dB...

Page 6: ...tion Hydraulic Performance Dimensions 5 Head m Flow L min 0 00 2 00 4 00 6 00 8 00 10 00 12 00 14 00 16 00 18 00 20 00 0 50 100 150 200 250 300 350 400 450 Pantera Evolution Performance Chart Low 1450...

Page 7: ...h ventilation to keep ambient temperature below the motor s rated ambient temperature whenever the pump is running If installed in an enclosure pump house the enclosure must have adequate ventilation...

Page 8: ...ct voltage can cause fire or seriously damage pump and voids warranty d Voltage at pump must not be more than 6 above or 10 below motor nameplate rated voltage or pump may overheat causing overload tr...

Page 9: ...e o ring The original equipment O ring contains a permanent internal lubricant a Before removing trap lid SWITCH OFF POWER SUPPLY to pump b CLOSE SHUT OFF VALVES on suction and discharge pipes if pres...

Page 10: ...then automatically will return to low 9 Cleaning with a suction cleaner Backwashing filter Operating some water features such as jets or waterfalls Solar heating 5 sec Press hold for 5 seconds On eac...

Page 11: ...e through the gland nut and then through the gland as shown in Figure 2 6 Connect the control cable to the circuit board connectors marked High Speed and Low Speed as shown in Figure 3 7 Connect the o...

Page 12: ...is operating If leaks are noticed clean and grease the o rings or replace if necessary Check that there are no leaks from under the pump If there are this could be a sign of a leaking mechanical seal...

Page 13: ...st prime Low speed setting Clogged pipe strainer impeller filter system Pump must be primed make sure that the pump casing and strainer are full of water Refer priming instructions Make sure there are...

Page 14: ...ection of this manual Ensure motor fins are clean and fan is intact and free from blockages Ensure adequate ventilation and reduce ambient temperature Switch off the power to the pump Tighten the casi...

Page 15: ...AL PACK OF 25 801303 12 DIFFUSER 303460K 13 IMPELLER 506840K 14 SEPERATOR PLATE 408730 15 CASING ASSEMBLY INCLUDES ITEMS 16 17 18 19 801200 16 CASING PANTERA POOL SEE CASING ASSEMBLY 17 STRAINER BASKE...

Page 16: ...b www pentair co nz International Australia New Zealand Phone 61 3 9709 5800 Fax 61 3 9709 5888 Information contained here in remains the property of Pentair Pty Ltd Any reproduction display publicati...