background image

6

PUMP SERVICE

CAUTION: Always turn power off and drain the pump before 

servicing. If pump is below the water level of the pool, close 

shut-off valve on both suction and discharge lines.
Step 1:

 Disconnect the power and remove drain plugs.

Step 2:

 Remove strainer lid; let drain.

Step 3:

 Disconnect piping.

Step 4:

 Remove clamp by turning tee handle.

CAUTION: Be sure pump is drained and pressure has been 

released before removing clamp.
Step 5:

 Remove the case.

Step 6:

 Remove the impeller by turning counterclockwise. The 

best way to remove impeller is by inserting a screwdriver in the 
blade area and sharply hitting screwdriver with a rubber hammer.

Step 7:

 The motor can be removed by unscrewing 4 bolts.

Step 8:

 Install new seal following instructions in seal 

repair package.

Step 9:

 Inspect O-rings for knicks and cuts. If damaged, 

replace with new ones.

Step 10:

 Clean O-ring seat area. Lubricate O-rings with 

petroleum jelly.

Step 11:

 Attach motor to seal plate and base.

Step 12:

 Attach case to seal plate with clamp.

Step 13:

 Install pipe plugs.

Step 14:

 Connect piping.

Step 15:

 Fill pump with water.

Step 16:

 Replace strainer lid.

Step 17:

 Reconnect power.

TROUBLESHOOTING CHECKLIST 

(CAUTION: SHUT OFF POWER TO PUMP)

PROBLEM

POSSIBLE CAUSES

Pump will not prime.

• Stop motor, remove strainer lid, and fill case with water.
• Make sure suction line has no leaks, and that it slopes gradually from pump to pool with no high or 

low spots.

• Make sure pump shaft turns clockwise when viewed from motor end opposite shaft.
• Check for plugged impeller.
• Make sure the check valve is not sitting in sand or mud, and that it is not stuck shut.

Pump delivers water for a period 
of time, then stops pumping.

• Check for plugged impeller.
• Check for a suction leak.
• Check for blocked suction line.
• Check to see if impeller is rubbing.

Pump does not deliver 
rated capacity.

• Check for plugged impeller.
• Check for a suction leak.
• Check for a blocked suction line.
• Check to see if impeller is rubbing.

Motor overheats and shuts 
off (overload).

• Make sure motor is properly wired for the correct voltage.
• Check wire size - wire may be too small. See selection chart on page 3.
• Make sure the impeller is not rubbing against the pump case.

Motor fails or does not 
operate properly.

• If within warranty, return pump/motor unit to place of purchase (with proof of purchase) for exchange.

This information is for checking pool pump installations that are 
not operating properly. It is based on the premise that the installed 
system will consist of a swimming pool pump taking water from a pool 
and forcing it through a filter and back to the pool.

Warning: To guard against accidental personal injury, 

the electric power to the pump must be turned off when 

conducting the checking procedures outlined herein.

There are obvious exceptions, however, and authorized service 
personnel should take necessary safeguards against the hazard of 
electrical shock.

Summary of Contents for MYERS MSP10

Page 1: ...yers au 1 888 987 8677 On peut aussi visiter le site Myers au www femyers com Lea y siga todas las advertencias e instrucciones sobre seguridad antes de instalar o usar este producto El no seguir las...

Page 2: ...icable and all applicable local codes and ordinances California Proposition 65 Warning This product and related accessories contain chemicals known to the State of California to cause cancer birth def...

Page 3: ...cause damage to mechanical seal leakage and flooding WARNING Explosion hazard Never run pump against closed discharge valve To do so can cause high temperatures pump damage personal injury and proper...

Page 4: ...EP 1 General Tools and Materials Needed Electrical cable with ground wire Ground fault circuit breaker Rigid 1 1 2 PVC pipe and fittings or reinforced flex hose and hose clamps Pump Filter Backwash va...

Page 5: ...3 4 115 11 8 100 160 250 385 600 MSP7 15 3 4 230 5 9 400 630 990 1545 2405 MSP10 10 1 115 14 4 128 200 310 485 MSP10 20 1 230 7 2 300 475 660 1030 1650 MSP15 10 1 1 2 115 20 8 142 222 345 MSP15 25 1 1...

Page 6: ...that it slopes gradually from pump to pool with no high or low spots Make sure pump shaft turns clockwise when viewed from motor end opposite shaft Check for plugged impeller Make sure the check valv...

Page 7: ...Qty No No Description Req d 1 25051A008 3 4 HP Motor MSP7 1 1 25051A009 1 HP Motor MSP10 1 1 25051A010 1 1 2 HP Motor MSP15 1 2 05059A318 Slinger 1 3 25053A000 Shaft Seal 1 4 19101A010 Cap Screw 3 8...

Page 8: ...repair or replace defective products at F E MYERS s choice You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as...

Page 9: ...tric Code ou au code canadien de l lectricit selon le cas et tous les d crets et codes en vigueur de la municipalit Avertissement li la Proposition 65 de la Californie Ce produit et les accessoires co...

Page 10: ...laisser les enfants utiliser ce produit 3 AVERTISSEMENT Risques d lectrocution Cet appareil ne peut tre connect qu une prise prot g e par un interrupteur de fuite la terre Si vous ne pouvez confirmer...

Page 11: ...xibles Connectez la canalisation d aspiration venant de l cumeur de la piscine et ou de l orifice de vidage l orifice d entr e de la pompe Si la pompe est install e c t d une piscine hors terre une va...

Page 12: ...s ou un disjoncteur doit tre install sur ce circuit voir tableau de fusibles Si la pompe est branch e sur une prise existante vous risquez d avoir une tension insuffisante sur le moteur de faire grill...

Page 13: ...t ainsi endommager la pompe et les tuyaux AVERTISSEMENT Ne pas utiliser de liquide antigel courant Les liquides antigel pour automobile sont fabriqu s avec de l thyl ne glycol un produit tr s toxique...

Page 14: ...fuit V rifiez si la canalisation d aspiration est bouch e V rifiez si l impulseur frotte Le moteur surchauffe et s arr te surcharge Assurez vous que le moteur est correctement c bl en fonction de la t...

Page 15: ...MSP7 1 1 25051A009 Moteur 1 HP MSP10 1 1 25051A010 Moteur 1 1 2 HP MSP15 1 2 05059A318 Chasse goutte 1 3 25053A000 Joint de scell e d arbre 1 4 19101A010 Vis d assemblage 3 8 po x 1 po 6 5 25054B001 I...

Page 16: ...istent r parer ou remplacer au choix de F E MYERS les produits qui se r v leraient d fectueux L Acheteur s engage payer tous les frais de main d uvre et d exp dition du produit couvert par sa garantie...

Page 17: ...ertencia de la Proposici n 65 de California Este producto y accesorios relacionados contienen sustancias qu micas reconocidas en el Estado de California como causantes de c ncer malformaciones cong ni...

Page 18: ...illo en el agua y da ar la bomba 14 GUARDE ESTAS INSTRUCCIONES Hay que cebar la bomba Aseg rese de que est llena de agua antes de ponerla en funcionamiento En caso de no hacerlo se producir n da os en...

Page 19: ...generales necesarios Cable el ctrico con conductor de conexi n a tierra Interruptor accionado por corriente de p rdida a tierra Tuber a y accesorios de 1 1 2 de cloruro de polivinilo r gido o manguera...

Page 20: ...Se deber usar una caja de fusibles o un disyuntor de circuito en esta l nea v ase la tabla de fusibles Hacer la conexi n en los enchufes existentes podr a causar que el motor reciba un voltaje bajo lo...

Page 21: ...ados com nmente con glicol etileno el cual es altamente venenoso y no se evapora El alcohol met lico es tambi n altamente venenoso pero se evaporar si se expone lo suficiente a la atm sfera Muchas sol...

Page 22: ...fugas en la succi n Compruebe que la l nea de succi n no est obturada Compruebe que el impulsor no est rozando El motor se sobrecalienta y se apaga sobrecarga Aseg rese de que el motor est cableado c...

Page 23: ...de fuerza MSP7 1 1 25051A009 Motor de 1 caballo de fuerza MSP10 1 1 25051A010 Motor de 1 1 2 caballos de fuerza MSP15 1 2 05059A318 Anillo lubricante del v stago 3 25053A000 Sello de v stago 4 19101A...

Page 24: ...es que F E MYERS repare o reemplace los productos defectuosos a juicio de F E MYERS Usted deber pagar todos los cargos de mano de obra y de env o asociados con esta garant a y deber solicitar el serv...