IMPORTANT INSTRUCTIONS BEFORE INSTALLATION

Failure to follow these instructions may cause serious bodily injury and/or property damage.

Save this manual for future reference. 

This is the safety alert symbol.

 When you see this symbol 

on your pump or in this manual, look for one of the following 
signal words and be alert to the potential for personal injury:

DANGER 

warns about hazards that 

will

 cause serious personal 

injury, death or major property damage if ignored.

WARNING 

warns about hazards that 

can

 cause serious personal 

injury, death or major property damage if ignored.

CAUTION 

warns about hazards that 

will

 or 

can

 cause minor 

personal injury or property damage if ignored.
The label

 NOTICE 

indicates special instructions which are 

important but not related to hazards.

Carefully read and follow all safety instructions in this manual 

and on pump.

Keep safety labels in good condition. 
Replace missing or damaged safety labels.

WARNING. Severe personal injury or death could result from 

improperly sizing the pump, or from using it for any purpose 

other than as an in-ground pool pump.

 Hazards may include, 

but are not limited to, electrical shock, fire, flooding, suction 
entrapment, or structural failure of the pump or other system 
component.

WARNING. Pressure testing hazards.

•  Do not allow people to work around components under test.
•  Post appropriate warnings and barriers around pressurized 

equipment.

•  Test for the minimum time allowed by local codes.
•  If the equipment is located in a separate room, close and lock 

the door and post warning signs.

ELECTRICAL

This pump must be wired through a Ground Fault Circuit 
Interrupter (GFCI) to protect the circuit. To reduce the risk of 
electrical shock, connect the green terminal on the pump to the 
grounding terminal of your electrical service or supply panel. Use 
a conductor at least as large as the wires conducting power to the 
pump. Refer to local or national codes for details.
Installations must comply with the National Electrical Code or the 
Canadian Electrical Code, as applicable, and all applicable local 
codes and ordinances.

California Proposition 65 Warning

 This product and related accessories contain 

chemicals known to the State of California to cause cancer, birth 
defects or other reproductive harm

GENERAL

Pool main drain installation must comply with current local and 
national building, electrical, plumbing and pool/spa codes, as 
applicable.
Prime the pump (fill the pump and piping system with water) 
before starting it for the first time. If you do not get satisfactory 
circulation within 5 minutes, stop the pump and reprime it. Do 
not allow the pump to run for an extended period of time with no 
water moving. In these conditions, the pump may overheat and 
start a fire or possibly explode.

WARNING. Explosion hazard, with risk of severe 

injury or death.

 Always stop the pump and relieve all 

pressure in the system before adjusting or releasing 

any fastenings. Make sure there is no air in the system (use the 
air bleed valve on the pool filter to  release any trapped air in the 
system). NEVER adjust, loosen or tighten any lid clamps or bolts 
while the system is pressurized.

WARNING. Risk of electrical shock – can burn or 

kill. 

Always disconnect power to the pump at the 

circuit breaker before servicing or working on the 
pump. Make sure that no one can connect the power 

without your knowledge and consent.

WARNING. Fire and burn hazard.

 Do not allow leaves 

and debris to collect around the pump. Do not allow 
children around the pump and filter areas. Allow the 
pump motor to cool for 20 minutes before working  
on it.

DANGER. Hazardous Suction. Can trap hair or body, causing 

severe injury or death.

•  Do not block circulation pump suction. MAKE SURE that all main 

drains are correctly installed, with anti-entrapment covers, 
listed to ASME A112.19.8, screw-fastened in place, and that 
any vacuum outlets are protected by self-closing, self-latching 
vacuum covers listed to IAPMO SPS-4 2000.

•  Keep small children under close adult supervision around the 

pool at all times.

•  NEVER allow anyone (adult or child) to sit on a pool main drain.
•  Very small children sometimes think that a main drain is really 

a place to “go potty”. Don’t let them do this!

B

od

y

F

or

eA

rm

Upp

er

Arm

Leg Jo

int

Leg

 J

oi

nt

Leg 

Joi

nt

Leg

 Jo

in

t

Summary of Contents for MYERS MSP10

Page 1: ...yers au 1 888 987 8677 On peut aussi visiter le site Myers au www femyers com Lea y siga todas las advertencias e instrucciones sobre seguridad antes de instalar o usar este producto El no seguir las...

Page 2: ...icable and all applicable local codes and ordinances California Proposition 65 Warning This product and related accessories contain chemicals known to the State of California to cause cancer birth def...

Page 3: ...cause damage to mechanical seal leakage and flooding WARNING Explosion hazard Never run pump against closed discharge valve To do so can cause high temperatures pump damage personal injury and proper...

Page 4: ...EP 1 General Tools and Materials Needed Electrical cable with ground wire Ground fault circuit breaker Rigid 1 1 2 PVC pipe and fittings or reinforced flex hose and hose clamps Pump Filter Backwash va...

Page 5: ...3 4 115 11 8 100 160 250 385 600 MSP7 15 3 4 230 5 9 400 630 990 1545 2405 MSP10 10 1 115 14 4 128 200 310 485 MSP10 20 1 230 7 2 300 475 660 1030 1650 MSP15 10 1 1 2 115 20 8 142 222 345 MSP15 25 1 1...

Page 6: ...that it slopes gradually from pump to pool with no high or low spots Make sure pump shaft turns clockwise when viewed from motor end opposite shaft Check for plugged impeller Make sure the check valv...

Page 7: ...Qty No No Description Req d 1 25051A008 3 4 HP Motor MSP7 1 1 25051A009 1 HP Motor MSP10 1 1 25051A010 1 1 2 HP Motor MSP15 1 2 05059A318 Slinger 1 3 25053A000 Shaft Seal 1 4 19101A010 Cap Screw 3 8...

Page 8: ...repair or replace defective products at F E MYERS s choice You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as...

Page 9: ...tric Code ou au code canadien de l lectricit selon le cas et tous les d crets et codes en vigueur de la municipalit Avertissement li la Proposition 65 de la Californie Ce produit et les accessoires co...

Page 10: ...laisser les enfants utiliser ce produit 3 AVERTISSEMENT Risques d lectrocution Cet appareil ne peut tre connect qu une prise prot g e par un interrupteur de fuite la terre Si vous ne pouvez confirmer...

Page 11: ...xibles Connectez la canalisation d aspiration venant de l cumeur de la piscine et ou de l orifice de vidage l orifice d entr e de la pompe Si la pompe est install e c t d une piscine hors terre une va...

Page 12: ...s ou un disjoncteur doit tre install sur ce circuit voir tableau de fusibles Si la pompe est branch e sur une prise existante vous risquez d avoir une tension insuffisante sur le moteur de faire grill...

Page 13: ...t ainsi endommager la pompe et les tuyaux AVERTISSEMENT Ne pas utiliser de liquide antigel courant Les liquides antigel pour automobile sont fabriqu s avec de l thyl ne glycol un produit tr s toxique...

Page 14: ...fuit V rifiez si la canalisation d aspiration est bouch e V rifiez si l impulseur frotte Le moteur surchauffe et s arr te surcharge Assurez vous que le moteur est correctement c bl en fonction de la t...

Page 15: ...MSP7 1 1 25051A009 Moteur 1 HP MSP10 1 1 25051A010 Moteur 1 1 2 HP MSP15 1 2 05059A318 Chasse goutte 1 3 25053A000 Joint de scell e d arbre 1 4 19101A010 Vis d assemblage 3 8 po x 1 po 6 5 25054B001 I...

Page 16: ...istent r parer ou remplacer au choix de F E MYERS les produits qui se r v leraient d fectueux L Acheteur s engage payer tous les frais de main d uvre et d exp dition du produit couvert par sa garantie...

Page 17: ...ertencia de la Proposici n 65 de California Este producto y accesorios relacionados contienen sustancias qu micas reconocidas en el Estado de California como causantes de c ncer malformaciones cong ni...

Page 18: ...illo en el agua y da ar la bomba 14 GUARDE ESTAS INSTRUCCIONES Hay que cebar la bomba Aseg rese de que est llena de agua antes de ponerla en funcionamiento En caso de no hacerlo se producir n da os en...

Page 19: ...generales necesarios Cable el ctrico con conductor de conexi n a tierra Interruptor accionado por corriente de p rdida a tierra Tuber a y accesorios de 1 1 2 de cloruro de polivinilo r gido o manguera...

Page 20: ...Se deber usar una caja de fusibles o un disyuntor de circuito en esta l nea v ase la tabla de fusibles Hacer la conexi n en los enchufes existentes podr a causar que el motor reciba un voltaje bajo lo...

Page 21: ...ados com nmente con glicol etileno el cual es altamente venenoso y no se evapora El alcohol met lico es tambi n altamente venenoso pero se evaporar si se expone lo suficiente a la atm sfera Muchas sol...

Page 22: ...fugas en la succi n Compruebe que la l nea de succi n no est obturada Compruebe que el impulsor no est rozando El motor se sobrecalienta y se apaga sobrecarga Aseg rese de que el motor est cableado c...

Page 23: ...de fuerza MSP7 1 1 25051A009 Motor de 1 caballo de fuerza MSP10 1 1 25051A010 Motor de 1 1 2 caballos de fuerza MSP15 1 2 05059A318 Anillo lubricante del v stago 3 25053A000 Sello de v stago 4 19101A...

Page 24: ...es que F E MYERS repare o reemplace los productos defectuosos a juicio de F E MYERS Usted deber pagar todos los cargos de mano de obra y de env o asociados con esta garant a y deber solicitar el serv...