MASTERTEMP
™
Pool and Spa Heater Installation and User’s Guide P/N 475106 Rev. D 1/2016
6
| Section
Diagnostic LED
1 Flash
- Air Flow Fault
2 Flashes - Flame No Call For Heat
3 Flashes - Ignition Lockout
Flame Current
Check Point
Figure 5.
SAFETY CONTROLS,
(continued)
OPERATION OF IGNITION MODULE
The Ignition Module
, (see Figure 5),
is microprocessor based and
operates on 24VAC supplied by the transformer. The control utilizes
a microprocessor to continually and safely monitor, analyze, and
control the proper operation of the gas flame holder. The module
with the presence of the flame sensor, using flame rectification,
allows the heater to operate.
TEMPERATURE SETTING
The heater comes factory set at 25.6° C (78° F). for the pool mode and 37.8° C (100° F). for the spa mode. Using the up
and down arrows, you can set the pool/spa thermostats to a minimum temperature of 18.3° C (65° F.), or a maximum of
40° C (104° F). If you desire to heat only one body of water, the thermostat is capable of an off mode. As an example, if
you only wish to heat the spa and not the pool, simply depress and hold the pool down arrow, and the thermostat will
lower its setting to 18.3° C (65° F.) then go to an off mode. See below to change the heater’s factory set temperature
settings.
MAXIMUM TEMPERATURE SET POINT
1. Unbolt and remove the door panels (see Figure 6).
2. Access the control panel board on the underside of the top cover.
Locate the yellow button on the corner of the control board.
3. Push the
Max. Temp. Set Point
button on the back of the
control board (see Figure 7).
The following sequence should happen:
1.
The unit turns on and the
POOL ON
light will
turn on.
2.
Press the
TEMP
or
TEMP
button (on TOP of the
control panel) to set maximum pool temperature.
3.
Wait up to 30 seconds; the
POOL ON
light will turn off
and the
SPA ON
light will turn on. To override the time
delay, push the
Max. Temp. Set Point
button again.
4.
Press the
TEMP
or
TEMP
button on the control
panel and set maximum spa temperature to 40°C
(104° F) or less.
5.
Wait up to 30 seconds; the
SPA ON
light will turn off
and the unit will shut down. To override the time delay,
push the
Max. Temp. Set Point
button again.
6.
Reinstall the access door panels.
Door
Access
Panel
Top Panel
Door
Access Panel
Figure 6.
S1
SE
T
M A
X
S1
SET
M A
X
Figure 7.
1. Operations