External Control with IntelliComm
®
Communication Center
The IntelliFlo
®
pump can be remotely controlled by the Pentair IntelliComm Communication
Center using the RS-485 communications cable. The IntelliComm provides four pairs of input
terminal connections. These inputs are actuated by either 15 - 240 VAC or 15 - 100 VDC. Using
the device’s inputs, the programmed IntelliFlo
®
pump speeds can be controlled.
Note: For the IntelliFlo
®
pump to accept commands from IntelliComm, the pump must be
in the “Running Schedules” mode (LED above the Start/Stop button lit).
If more than one input is active the highest number will be communicated to the IntelliFlo
®
pump. The IntelliComm will always communicate to pump using ADDRESS #1.
Program number priority is as follows:
Example: If programs 1 and 2 are activated, program
2 will run, regardless of the assigned speed (RPM). The higher program number (2 being
higher) will always take priority. The following table shows the wiring terminal descriptions for
IntelliComm.
External Control
IntelliComm Communication Center
Terminal
Number
Terminal Name
Voltage
Maximum
Current
Phase Type
Frequency
1-2
Power Supply
100 - 240 VAC
100 mA
1 Input
50/60 Hz
3-4
Program 1
15 -240 VAC
or
15 - 100 VDC
1 mA
1 Input
50/60 Hz
5-6
Program 2
15 -240 VAC
or
15 - 100 VDC
1 mA
1 Input
50/60 Hz
7-8
Program 3
15 -240 VAC
or
15 - 100 VDC
1 mA
1 Input
50/60 Hz
9-10
Program 4
15 -240 VAC
or
15 - 100 VDC
1 mA
1 Input
50/60 Hz
11
12
RS-485
+ Data: Yellow
- Data: Green
-5 to +5 VDC
5 mA
1 Output
N/A
Ground
English